GAS INSTRUCTIONS
REMOVE CONTROL KNOBS & CONTROL PANEL FOR LEAK TESTING
You will need: Phillips screwdriver.
1) Remove control knobs.
2) Remove screw and washer from back of control panel with a Phillips screwdriver.
3) Tilt the back edge of the control panel up. Push in on the front edge to release
locking tabs. Carefully pull control panel away from frame.
4) Disconnect the igniter wires from the ignition module.
5) Replace control panel when Leak Check is completed.
GAS INSTRUCTIONS
1
2
3
4
CHECK FOR GAS LEAKS
ƽ WARNING: You should check for gas leaks every time you
disconnect and reconnect a gas fi tting.
Note: All factory-made connections have been thoroughly checked for gas leaks. The
burners have been fl ame-tested. As a safety precaution however, you should recheck
all fi ttings for leaks before using your Weber
®
Gas Barbecue. Shipping and handling
may loosen or damage a gas fi tting.
ƽ WARNING: Perform these leak checks even if your barbecue
was dealer or store assembled.
You will need: a soap and water solution, and a rag or brush to apply it.
Note: Since some leak test solutions, including soap and water, may be slightly
corrosive, all connections should be rinsed with water after checking for leaks.
If your grill has a side burner make sure the side burner is off.
To perform leak checks: open cylinder valve by turning the cylinder valve hand-wheel
counterclockwise.
ƽ WARNING: Do not ignite burners when leak checking.
Check for leaks by wetting the connections with the soap and water solution and
watching for bubbles. If bubbles form or if a bubble grows, there is a leak.
ƽ DANGER
Do not use an open fl ame to check for gas leaks. Be sure
there are no sparks or open fl ames in the area while you
check for leaks. Sparks or open fl ames will result in a fi re or
explosion, which can cause serious bodily injury or death
and damage to property.
Check:
1) Hose-to-manifold connection.
ƽ WARNING: If there is a leak at connection (1), retighten the
tting with a wrench and recheck for leaks with soap and
water solution. If a leak persists after retightening the fi tting,
turn OFF the gas. DO NOT OPERATE THE GRILL. Contact
the Customer Service Representative in your area using the
contact information on our web site. Log onto www.weber.
com
®
.
2) Regulator-to-Cylinder connection.
3) The hose-to-regulator connection.
4) Valves-to-manifold connections.
ƽ WARNING: If there is a leak at connections (2), (3) or (4),
turn OFF the gas. DO NOT OPERATE THE GRILL. Contact
the Customer Service Representative in your area using the
contact information on our web site. Log onto www.weber.
com
®
.
When leak checks are complete, turn gas supply OFF at the source and rinse