OPERATING
ƽ WARNING: Only use the Weber
®
Tank Enclosure Kit outdoors
in a well-ventilated area. Do not use in a garage, building,
breezeway or any other enclosed area.
ƽ WARNING: Your Weber
®
Tank Enclosure Kit shall not be used
under an unprotected combustible roof or overhang.
ƽ WARNING: Your Weber
®
Tank Enclosure Kit is not intended to
be installed in or on recreational vehicles and/or boats.
ƽ WARNING: Keep any electrical supply cord and the fuel
supply hose away from any heated surface.
c). If the remote LP cylinder enclosure has four sides, a top and a bottom, and is intended
for installation in a built-in “island” enclosure;
1). At least one ventilation opening (a hole or group of holes, for the purpose
of ventilation) needs to be on one side of the enclosure that communicates
with the outside of the “island” structure. If a gas leak should occur or the
LP cylinder should vent in the LP cylinder enclosure, the gas should not be
allowed to vent or migrate into the empty or “hollow” area of the “island”.
Ventilation openings should only communicate with the outside of the “island”
structure, so that the gas can dissipate outside of the “island” structure. The
ventilation opening should be located within 5 inches (127mm) of the top of
the enclosure, and should have a total free area of 20 square inches. (This
relates to 1 square inch of ventilation area, per pound of stored fuel).
2). At least one ventilation opening (a hole or group of holes, for the purpose of
ventilation) needs to be on one side of the enclosure that communicates with
the outside of the “island” structure, at the bottom. If a gas leak should occur
or the LP cylinder should vent in the LP cylinder enclosure, the gas should not
be allowed to vent or migrate into the empty or “hollow” area of the “island”.
Ventilation openings should only communicate with the outside of the “island”
structure, so that the gas can dissipate outside of the “island” structure. The
ventilation opening should be located within 5 inches (127mm) of the bottom
of the enclosure, and should have a total free area of 10 square inches. (This
relates to 1/4 square inch of ventilation area, per pound of stored fuel).
3). The minimum size of the ventilation hole (s) should not be less than 1/4 inch
(6.35mm).
d). The remote LP cylinder enclosure should be constructed with non-combustible
materials. The remote LP cylinder enclosure should isolate the LP cylinder from the
burner compartment, so that it provides shielding from radiation, be a fl ame barrier
and provide protection from foreign material such as hot drippings.
e). There should be a minimum of 2 inches (50.8mm) between the ground and the fl oor of
the remote LP cylinder enclosure.
f). The LP cylinder valve should be readily accessible for hand operation. A door on the
remote LP cylinder enclosure to gain access to the LP cylinder valve is acceptable,
provided it is non-locking and can be opened without the use of tools.
ƽ DANGER
Use of any other hose and regulator assembly could be
dangerous, and may not provide adequate gas supply to
the Summit
®
Built-In gas grill, and could result in a fi re or an
explosion causing serious bodily injury or death, and damage
to property.
ƽ DANGER
Failure to use the Summit
®
Built-In Tank Cabinet for a 20 lb
cylinder or failure to build a LP cylinder enclosure for a 20 lb
cylinder following the requirements for ventilation, cylinder
retention and separation of the LP cylinder from a heat
source, listed in the ANSI Standard for Outdoor Cooking Gas
Appliances, ANSI Z21.58 CSA 1.6, could be dangerous, and
could result in a fi re or an explosion causing serious bodily
injury or death and damage to property.
If you do not follow the DANGER statements exactly, the Warranty on the Summit
®
Built-
In gas grill will be voided.
ƽ WARNING: Never store an extra (spare) LP cylinder under or
near the Weber
®
gas barbecue.
ƽ WARNING: Keep the ventilation openings of the cylinder
enclosure free and clear of debris.
ƽ WARNING: Turn off the gas at the LP gas supply cylinder
when the outdoor cooking gas appliance is not in use.
ƽ WARNING: Never store an outdoor cooking gas appliance
indoors unless the LP cylinder is disconnected and removed
from the outdoor cooking gas appliance.
ƽ WARNING: LP Cylinders must be stored outdoors out of
the reach of children and must not be stored in a building,
garage, or any other enclosed area.
ƽ WARNING: The LP pressure regulator and hose assembly
supplied with the Weber
®
Tank Enclosure Kit must be used.
Replacement LP pressure regulators and hoses must be
obtained from Weber-Stephen Product Co.
GAS SUPPLY
BUILT-IN TANK ENCLOSURE INSTRUCTIONS