CONNECT FILLED LP TANK
WARNING: Make sure that the LP tank valve is
closed. Close by turning clockwise.
Hook the LP tank onto the fuel scale. Loosen the tank
lock wing nut. Swing the tank lock down. Tighten the wing
nut. Figure 25.
Figure 25
Tank lock wing
nut
Remove the tape and packaging from the hose and regulator.
Route the hose so it will not interfere with the scale
indicator rod.
The hose and regulator are connected in the following manner:
Slide back the collar of the quick disconnect on the tank
valve. Push the male fitting of the regulator into the quick
disconnect, and maintain pressure. Slide the collar closed.
Figure 26 (a). Figure 26 (b) shows the quick disconnect
engaged and various components of the tank and
regulator. Regulator vent hole should be at 3, 6, or 9
o'clock. It should not be pointed up. Figure 26 (c).
Figure 26
Turn so regulator vent
does not collect water
Hose
Quick disconnect
engaged
Valve handwheel
close clockwise
Tank valve
Collar
Male
fitting
Pressure
relief valve
Tank
Regulator
Regulator
vent
(a)
(b)
(c)