Weber 220 Gas Grill User Manual


 
GAS INSTRUCTIONS - Q 100, 120 (CONTINUED)
Check for gas leaks:
1) Regulator to butane/propane cartridge connection.
m WARNING: If there is a leak at connection (1), remove butane/
propane cartridge. Do not operate grill. Use a different butane/
propane cartridge and recheck for leaks with soap-and-water
solution. If a leak persists after retightening the butane/propane
cartridge, turn OFF the gas. DO NOT OPERATE THE GRILL. Contact
the Customer Service Representative in your area using the contact
information on our web site. Log onto www.weber.com
®
.
Check:
2) Valve-to-regulator connections.
m WARNING: If there is a leak at connection (2) turn OFF the gas.
DO NOT OPERATE THE GRILL. Contact the Customer Service
Representative in your region using the contact information on our
web site. Log onto www.weber.com
®
.
When leak checks are complete, turn gas supply OFF at the source and
rinse connections with water.
2)
1)
Connecting the Butane/Propane Cylinder
Use butane/propane cylinders with a minimum capacity of 5 kg and a
maximum capacity of 13 kg.
You will need: butane/propane cylinder, a soap-and-water solution and a rag
or brush to apply it.
The regulator illustrations shown in this manual may not be similar to the
one you are using for your barbecue, due to different country or regional
regulations.
Some regulators push ON to connect and pull OFF to disconnect, others
have a nut with a left-hand thread that connects to the cylinder valve. Follow
specific regulator connection instructions.
Position the regulator so that the vent-hole faces downwards.
1) Mix the soap and water.
2) Turn on the cylinder valve.
3) Check for leaks by wetting the fitting with the soap-and-water solution
and watching for bubbles. If bubbles form, or if a bubble grows, there is
a leak.
GAS INSTRUCTIONS - Q 200, 220
Hose
Regulator
Valve hand-wheel -
close clockwise
Regulator vent hole.
COUNTRY GAS TYPE & PRESSURE
Demark, Sweden, Norway, Finland, Iceland,
The Netherlands, Hungary, Czech Republic
I
3B/P
- 30mbar
United Kingdom, France, Spain, Portugal, Belgium,
Ireland, Greece, Luxembourg, Italy, Switzerland
I
3+
- 28-30 / 37mbar
Germany, Austria
I
3B/P
- 50mbar
CONSUMPTION DATA
Propane/Butane Main Burner. Max
kW(Hs)
3.7
gm(Hs)
264