Special offers from our partners!
Find Replacement BBQ Parts for 20,308 Models. Repair your BBQ today.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.
16
VF4000-CMN/P OPERATING INSTRUCTIONS (MILLIVOLT VALVES)
FOR YOUR SAFETY READ BEFORE LIGHTING
• Do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone.
• If your gas supplier cannot be reached, call the fire department.
C. Use only your hand to push in or turn the gas control knob.
Never use tools. If the knob will not push in or turn by hand,
do not try to repair it, call a qualified service technician. Force
or attempted repair may result in a fire or an explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and
any gas control which has been under water.
A. This appliance has a pilot which must be lighted by hand.
When lighting the pilot, follow these instructions exactly.
B. BEFORE OPERATING smell all around the appliance area for
gas. Be sure to smell next to the floor because some gas is
heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Extinguish any open flame.
• Open windows.
• Do not light any appliance.
• Do not touch any electrical switches.
TO TURN OFF GAS TO APPLIANCE
1. Turn remote wall switch “OFF.” The pilot will remain lit for
normal service.
2. For complete shutdown, turn remote wall switch to “OFF.”
3. Access the left side louver.
4. Depress gas control knob slightly and turn clockwise
to “OFF.” Do not force.
5. Close the side louver.
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information above on this page.
2. Access left side louver.
3. Turn remote wall switch to “OFF.”
4. Verify main line shut-off valve is open.
5. Push in gas control knob slightly and turn clockwise
to “OFF.”
Note: Knob cannot be turned from “PILOT” to “OFF”
unless the knob is pushed in slightly. Do not force.
6. Wait five (5) minutes to clear out any gas. If you then smell
gas, STOP! Follow “B” in the safety information above on this
page. If you do not smell gas, go to the next step.
7. Push in gas control knob slightly and turn counterclockwise
to “PILOT.”
8. Push in control knob all the way and hold in. Immediately
light the pilot by triggering the spark ignitor (pushing red
button) until pilot lights. Continue to hold the control knob in
for about 1 ¹⁄₂ minutes after the pilot is lit. Release knob and
it will pop back up. Pilot should remain lit. If it goes out,
repeat steps 5 through 8.
• If knob does not pop up
when released, stop and
immediately call your
service technician or gas
supplier.
• If pilot will not stay lit after
several tries, turn the control knob to “OFF” and call your
service technician or gas supplier.
9. Turn gas control knob counterclockwise to “ON.”
10. Close the side louver.
Note: If the gas valve is turned directly from the “ON” to “OFF”
position, the valve will latch in the “OFF” position for 60 seconds.
Thermopile
Ignitor
Thermocouple
EA
TPTH TP TH
P
I
L
O
T
P
I
L
O
T
O
N
it
O
F
F
SIT Millivolt
Valve
Gas Control Knob
Piezo Ignitor
Flame Adjustment Knob
Honeywell
Millivolt Valve
Gas Control Knob
Spark Ignitor
O
N
O
F
F
P
I
L
O
T
L
O
H
I
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.