Special offers from our partners!
Find Replacement BBQ Parts for 20,308 Models. Repair your BBQ today.
Fire & Ice • 23
WARNING
• Do not use grill until leak checked.
• If leak is detected at any time, STOP and call the Fire Department.
• If you cannot stop a gas leak, close LP tank valve and call LP gas
supplier or your fire department!
immediately
Leak Testing Valves, Hoses and Regulator
Turn grill control knob to off.
Correct
before proceeding
1.
2. Be sure connector is tightly connected to LP tank.
3. Completely open LP tank valve by turning hand wheel counter clockwise. If you hear a
, turn gas off immediately. There is a major leak at the connection.
.
4. Brush soapy solution onto following connections:
rushing sound
5. bubbles appear, there is a leak. Close LP tank valve immediately and
retighten connections. all for
replacement parts. Order new parts by giving the serial, model number and name of items
needed to the Grill Service Center at 1-800-435-5194 U.S. or 1-800-387-6057 CAN.
6. Always close LP tank valve after performing leak test by turning hand wheel clockwise.
"If growing"
If leaks cannot be stopped "do not try to repair". C
Regulator connection
LP tank valve
connection