NATURAL GAS REQUIREMENTS -
Inlet Connection: 1/2" NP with 3/8" NPT reducer adapter.
Supply Pressure: 6" to 14" W.C.
Manifold Pressure: 5" W.C.
PROPANE GAS REQUIREMENTS -
Inlet Connection: 1/2" NP with 3/8" NPT reducer adapter.
Supply Pressure: 11" to 14" W.C.
Manifold Pressure: 10" W.C.
FIGURE 1 PROPANE HOOK-UP
SECTION 2: GAS REQUIREMENTS
IMPORTANT: Un robinet manuel d'isolement doit étre installé à l’extérieur de l’appareil, dans
un emplacement accessible avec l’unité installée dans la module. Assurez-vous que le robinet est
fermé avant de brancher l’appareil.
!
!
IMPORTANT: A manual gas shut off valve must be installed external to the appliance, in
a location accessible with the unit installed in the enclosure. Make sure the valve is turned
off prior to connecting the appliance.
FIGURE 2 NATURAL GAS HOOK-UP
Bottom of
unit
Coupling 1/2" NPT fitting
threading compound on
these threads must be
resistant to LP gas
L.P. Regulator hose
assembly 10" W.C.