Summit 21287 Gas Grill User Manual


 
5
LOCATING YOUR LP TANK ENCLOSURE
KIT
When determining a suitable location for your LP Tank
Enclosure Kit installation, give attention to concerns such
as proximity to traffi c paths, and keeping any gas supply
lines as short as possible. Never locate the Summit
®
LP
Tank Enclosure Kit in a garage, breezeway, shed, under an
unprotected overhang, or other enclosed area. Locate the LP
Tank Enclosure Kit and structure so there is enough room to
safely evacuate the area in case of a fi re.
Non-Combustible Surface
Any Surface
Any Surface
24 inches Any Surface
24 inches
24 inches
LP Tank
Enlosure
ASSEMBLY
CLEARANCE FROM COMBUSTIBLE SURFACES OR
STRUCTURES
ƽWARNING: Clearance from the outside walls of the
sides and back of the LP Tank Enclosure must be a
minimum of 24 inches any surface. Refer to “Typical Gas
Supply Installation” before starting installation.
ƽWARNING: The structure, “island” counter tops and
adjacent work areas for the LP Tank Enclosure must be
built from noncombustible materials only.
NOTE: If you have questions on what materials are consid-
ered noncombustible, contact you local building supplier or
fi re department.
e). There should be a minimum of 2 inches (50.8mm) be-
tween the ground and the fl oor of the remote LP cylinder
enclosure.
f). The LP cylinder valve should be readily accessible
for hand operation. A door on the remote LP cylinder
enclosure to gain access to the LP cylinder valve is ac-
ceptable, provided it is non- locking and can be opened
without the use of tools.
If your, licensed contractor or licensed plumber, builds an
LP cylinder enclosure following the guidelines in the ANSI
Standard for Outdoor Cooking Gas Appliances,
Z21.58 CSA 1.6, you need to order kit number (#21287),
which will contain the hose and regulator assembly, mount-
ing bracket for the regulator, connection fi ttings and LP tank
bracket for retaining the LP cylinder that must be used with
the Summit
®
Built-In gas grill. The hose and regulator in the
kit (#21287) is listed as part of the CSA listed Summit
®
Built-
In gas grill.
ƽDANGER
Use of any other hose and regulator assembly could
be dangerous, and may not provide adequate gas sup-
ply to the Summit
®
Built-In gas grill, and could result
in a fi re or an explosion causing serious bodily injury
or death and damage to property.
ƽDANGER
Failure to use the the Summit
®
Built-In Tank Cabinet
for a 20 lb cylinder or failure to build a LP cylinder en-
closure for a 20 lb cylinder following the requirements
for ventilation, cylinder retention and separation of
the LP cylinder from a heat source, listed in the ANSI
Standard for Outdoor Cooking Gas Appliances, ANSI
Z21.58 CSA 1.6, could be dangerous, and could result
in a fi re or an explosion causing serious bodily injury
or death and damage to property.
If you do not follow the DANGER statements exactly, the
Warranty on the Summit
®
Built-In gas grill will be voided.