Special offers from our partners!
Find Replacement BBQ Parts for 20,308 Models. Repair your BBQ today.
12
Liquid Propane (LP) Cylinder(s)
• The joint where the hose connects to the LP cylinder must
be leak tested each time the LP cylinder is reconnected.
For example, test each time the LP cylinder is refi lled.
• Be sure the regulator is mounted with the small vent hole
pointed downward so that it will not collect water. This
vent should be free of dirt, grease, bugs etc.
• The LP cylinder and connections supplied with your
Weber
®
gas barbecue have been designed and tested to
meet government, American Gas Association, and Under-
writers Laboratories requirements.
If you have questions about spare LP cylinders contact
Customer Service at 1(800) 446-1071.
• All LP tank supply systems must include a collar to pro-
tect the cylinder valve.
• The LP cylinder must be a 20-lb. size (18 1/4 inches high,
12 1/4 inches in diameter).
• The cylinder should be constructed and marked in ac-
cordance with the Specifi cations for LP - Gas Cylinders
of the U.S. Department of Transportation (D.O.T.) or the
National Standard of Canada, CAN/CSA-B339, Cylin-
ders, Spheres and Tubes or Transportation of Dangerous
Goods; and Commission, as applicable.
DOT 4BA240
00/02
(1)
(
2
)
GAS INSTRUCTIONS
Burner does not light
Flame is low in HIGH position.
Is gas supply off?
Is fuel hose bent or kinked?
Turn supply on
Straighten fuel hose.
If problems cannot be corrected by using these methods, please contact the Customer
Service Representative in your region using the contact information sheet provided with
your manual.
Problem Check Cure
Burners do not light. -or- Burners
have a small fl ickering fl ame in
the HIGH position. -or-
Barbecue temperature only
reaches 250˚ to 300˚ in the HIGH
position.
The excess fl ow safety device,
which is part of the barbecue to
cylinder connection, may have
activated.
To reset the excess fl ow safety
device turn all burner control
knobs and the cylinder valve OFF.
Disconnect the regulator from the
cylinder. Turn burner control knobs
to HIGH. Wait at least 1 minute.
Turn burner control knobs OFF.
Reconnect the regulator to the
cylinder. Turn cylinder valve on slowly.
Refer to “Lighting Instructions”.
TANK CABINET TROUBLESHOOTING