Nexgrill 720-0050-LP Gas Grill User Manual


 
GAS HOOK-UP
LP Gas Cylinder must be fitted with Overfill
Protection Device (OPD).
LP GAS HOOK-UP:
Ensure that the black plastic grommets on the LP
cylinder valve are in place and that the hose does not
come into contact with the grease tray or the grill
head.
CONNECTION:
Your grill is equipped with gas supply orifices for use
only with liquid propane gas. It is also equipped with
a high capacity hose/regulator assembly fo
r
connection to a standard 20lb. LP cylinder (18-1/4”
high, 12-1/4” diameter).
To connect the L.P. gas supply cylinder:
1. Make sure tank valve is in its full off position (turn
clockwise to stop).
2. Check tank valve to ensure it has proper external
male threads (type 1 connection pe
r
ANSIZ21.81).
3. Make sure all burner valves are in the of
f
position.
4. Inspect valve connections, port and regulato
r
assembly. Look for any damage or debris.
Remove any debris. Inspect hose for damage.
Never attempt to use damaged or obstructed
equipment. See your local LP gas dealer fo
r
repair.
5. When connecting regulator assembly to the
valve, hand tighten the nut clockwise to a
complete stop. Do not use a wrench to tighten.
Use of a wrench may damage the quick coupling
nut and result in a hazardous condition.
6. Open the tank valve fully (counterclockwise). Use
a soapy water solution to check all connections
for leaks before attempting to light the grill. See
below. If a leak is found, turn the tank valve of
f
and do not use the grill until a local LP gas deale
r
can make repairs.
To disconnect LP gas cylinder:
Only the pressure regulator and hose assembly
supplied with the grill should be used. Any
replacement pressure, regulator and hose
assembly must be specified by the grill
manufacturer.
This is a liquid propane configured grill.
Do not attempt to use a natural gas supply unless
the grill has been pre-configured for natural gas
use.
Total gas consumption (per hour) of 720-0050-LP
grill with all burners on “HI”:
Main burners 48,000 Btu/hr.
Side burner 12,000 Btu/hr.
Rotisserie burner 10,000 Btu/hr.
Total 70,000 Btu/hr.
The installation of this appliance must conform with
local codes or, in the absence of local codes, with
the national fuel gas code, ANSI Z223.1 Installation
in Canada must be in accordance with the
Standard CAN/CG A-B149.2 (installation code fo
r
gas burning appliances and equipment) and local
codes.
LP Gas Cylinder Requirements (20lb.Cylinder)
A
dented or rusty LP Gas Cylinder may be
hazardous and should be checked by your LP
supplier. Never use a cylinder with a damaged
valve. The LP gas cylinder must be constructed
and marked in accordance with the specifications
for LP gas cylinders of the U.S. Department o
f
Transportation (DOT), or the National Standard o
f
Canada, CAN/CSA-B339, Cylinders, Spheres and
Tubes for Transportation of Dangerous Goods; and
Commission.
The 20lb. cylinder must be provided with a shut of
f
valve terminating in an LP gas supply cylinde
r
valve outlet specified, as applicable, for connection
type QCC1 is the standard for compressed gas
cylinder valve outlet and inlet connection
A
NSI/CGA-V-1.
The cylinder supply system must be arranged fo
r
vapor withdrawal. The cylinder must include a
collar to protect the cylinder valve.
Manifold pressure: (operating): 10” water column
(W.C.), (non-operating): 11.2” water column (W.C.).
1. Turn the burner valves off.
2. Turn the tank valve off fully (turn clockwise to
stop).
Detach the regulator assembly from the tank valve by
turning the quick coupling nut counterclockwise
11