Napoleon Fireplaces N415-0232 Outdoor Fireplace User Manual


 
9
www.napoleonreplaces.com
OPERATION
WARNING!
If you do not follow these instrucons exactly a re or explosion may result causing prop
erty
damage, personal injury or loss of life.
Upon compleng the gas line connecon, a small amount of air will be in the lines. When rst lighng the
burner, it will take a few seconds for the lines to purge themselves of this air.
Once the purging is complete, the burner will light and operate as indicated in the instrucon manual. Subse
quent
lighng of the appliance will not require such pruging unless the gas supply has been disconnected.
FOR YOUR SAFETY READ BEFORE LIGHTING:
A. This appliance must be lit by hand while following these instrucons exactly.
B. Before operang smell all around the appliance area for gas and next to the oor because some gas is
heavier than air and will sele on the oor.
C. Use only your hand to turn the manual gas control valve. Never use tools. If the valve will not turn by hand,
do not try to repair it. Call a qualied service technician. Force or aempted repair may result in a re or
explosion.
D. Do not use this appliance if any part has been under water. Immediately call a qualied service technician to
inspect the appliance and replace any part of the control system and any gas control which has been underwater.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electric switch; Do not use any phone in your building.
Immediately call your gas supplier from a neighbour’s phone. Follow the gas supplier’s instrucons.
If you cannot reach your gas supplier, call the re department.
LIGHTING INSTRUCTIONS:
1. Locate the manual gas control valve.
2. Place the restarter near the burner ports on top of the burner. Light the restarter. For a Natural Gas unit,
turn on the ON/OFF valve slowly at the unit. For a LP unit, turn the valve in the LP tank counter clockwise all
the way and then turn on the ON/OFF valve slowly at the unit.
3. If the burner does not light before the re starter goes out, immediately turn the gas o.
4. Wait at least ve (5) minutes to clear out any gas. Then smell for gas including near the base of the unit. If you
smell gas, STOP! Refer to the safety informaon in the owner’s manual. If you don’t smell gas, repeat step 2.
TO TURN OFF GAS:
Turn the ON/OFF valve to the o posion at the unit for Natural Gas unit.
For LP unit, turn the ON/O valve to the o poson at the unit and then turn the valve on the LP tank to the
OFF posion clockwise.
Note: The propane regulator in this appliance is equipped with a low ow protecon device. Unless the
propane cylinder valve is opened before the appliance valve, the gas ow will be reduced resulng in a very
small ame. To reset this device, shut o the appliance valve, then the propane cylinder valve. Next, diconnect
the regulator adaptor from the tank and then reconnect. Follow the lighng procedure ensuring the propane
cylinder valve is opened before the unit is.