GENERAL INFORMATION
This appliance should be installed and serviced by a qualied installer to conform with local codes.
Installaon pracces vary from region to region and it is important to know the specics that apply to your
area, for example: in Massachuses State:
The appliance o valve must be a “T” handle gas cock.
The exible connector must not be longer than 36 inches.
The installaon must conform with local codes or in the absence of local codes, with the Naonal Fuel Gas
Code ANSI Z223.1/INFPA 54 in the United States or CSA B149.1, Natural and Propane Installaon code in
Canada.
The appliance and its individual shut o valve must be disconnected from the gas supply piping system during
any pressure tesng of the system at test pressures in excess of 1/2 psig (3.5kPa).
This appliance must be isolated from the gas supply piping system by closing its individual manual shut o valve
during any pressure tesng of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5kPa).
The following clearances to combusble materials must be maintained:
Sides (all around) - 24 inches (610mm)
Top - 72 inches (1.830m)
Always keep the appliance area clear and free from combusble materials, gasoline, and other ammable
vapours and liquids.
Do not locate appliance where it can get excessively
wet.
Do not use this appliance if any part has been
under water. Immediately call a qualied service
technician to inspect the unit and to replace any
part of the control system and any gas control
which has been underwater.