Napoleon Grills GPFP Outdoor Fireplace User Manual


 
W415-0638 / 04.24.08
8
Do not try to light any appliance.
Do not touch any electric switch; do not
use any phone in your building.
• Immediately call your gas supplier from a neighbour's
phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the re depart-
ment.
Upon completing the gas line connection, a small amount of
air will be in the lines. When rst lighting the burner, it will take
a few seconds for the lines to purge themselves of this air.
WARNING: Read and follow the safety and lighting instructions page in this manual and on labels on the appliance. IF YOU
DO NOT FOLLOW THESE INSTRUCTIONS PRECISELY, A FIRE OR EXPLOSION MAY RESULT AND YOU MAY BE
SERIOUSLY INJURED.
A. This appliance must be lit by hand while following these
instructions exactly.
B. Before operating smell all around the appliance area for
gas and next to the fl oor because some gas is heavier
than air and will settle on the fl oor
C. Use only your hand to turn the manual gas control valve.
Never use tools. If the valve will not turn by hand, do not
try to repair it. Call a quali ed service technician. Force
or attempted repair may result in a re or explosion.
D. Do not use this appliance if any part has been under
water. Immediately call a quali ed service technician to
inspect the appliance and replace any part of the con-
trol system and any gas control which has been under
water.
1. Locate the manual gas control valve.
2. Place the restarter near the burner ports on top of the
burner. Light the restarter. For a Natural Gas unit, turn
on the ON/OFF valve slowly at the unit. For a LP unit,
turn the valve in the LP tank counter clockwise all the
way and then turn on the ON/OFF valve slowly at the
unit.
3. If the burner does not light before the re starter goes
out, immediately turn the gas off.
4. Wait at least ve (5) minutes to clear out any gas. Then
smell for gas including near the base of the unit. If you
smell gas, STOP! Refer to the safety information in the
owner's manual. If you don't smell gas, repeat step 2.
Turn the ON/OFF valve to the off position at the unit for
Natural Gas unit.
For LP unit, turn the ON/OFF valve to the off position at
the unit and then turn the valve on the LP tank to the OFF
position clockwise.
OPERATION
FOR YOUR SAFETY READ BEFORE LIGHTING:
WHAT TO DO IF YOU SMELL GAS
LIGHTING INSTRUCTIONS
TO TURN OFF GAS
Once the purging is complete, the burner will light and operate
as indicated in the instruction manual. Subsequent lighting
of the appliance will not require such purging unless the gas
supply has been disconnected.
The propane regulator in this appliance is equipped with
a low fl ow protection device. Unless the propane cylinder
valve is opened before the patiofl ame valve, the gas fl ow
will be reduced resulting in a very small fl ame.
To reset this device, shut off the patiofl ame valve, then
the propane cylinder valve.
Next, disconnect the regulator adaptor from the tank and
then reconnect. Follow the lighting procedure ensuring
the propane cylinder valve is opened before the unit is.
NOTE