Monessen Hearth BWBC400 Fire Pit User Manual


 
11
43 3/4"
20"
21 13/16"
44"
SAFETY STRIP
9 1/2"
7 1/8"
3" X 36"
(
MIN.
)
21 3/8"
FLOOR LEVEL
5"
9 5/8"
(MIN.)
66"
(MIN.)
GAS OPENING
JUNCTION BOX
OPENING
HEARTH EXTENSION
FLOOR PROTECTION
With either type hearth extension minor shifting of the supporting floor or expansion and contraction may
eventually cause a crack to develop between the hearth extension and the face of the fireplace. To help
prevent the crack from developing, the hearth extension materials must be firmly fastened in place. Wall ties
should be screwed to the face of the fireplace and imbedded in the mortar joints of brick, stone, or other non-
combustible materials. The metal safety strip packed with the fireplace must be placed beneath the fireplace
and extended under the hearth extension or into a mortar joint of the hearth extension as shown by Figures 10,
11, and 12. In the event a crack does eventually develop, the metal safety strip will serve as a barrier to
prevent sparks or embers from falling from the fireplace onto combustible flooring materials.
The hearth extension must not block the side air vents, or air inlet louvers on the lower front of the fireplace.
These openings must be unobstructed to assure an adequate flow of cooling air around the firebox. If the
fireplace is equipped with a blower, or may be equipped with one at a later date, the hearth extension must not
prevent the removal of the lower louver panel for servicing the blower. Plan adequately by determining the
finished height of the hearth extension to be used and elevate the fireplace on a platform, if necessary, to
prevent obstructing the air openings or lower louvered panel.
FIGURE 11
The ability of insulating material to retard the transfer of heat may be expressed as either Thermal Conduc-
tance (C), Thermal Conductivity (K), or Thermal Resistance (R). The mathematical relationship of these
values and the formulas for converting one value to another is as follows:
C = K divided by the material thickness
(Example C = .43 divided by 1/2 (.50)
C = .86)
K = C multiplies by the material thickness
(Example K = .86 multiplied by 1/2 (.50)
K = .43)
R = The material thickness divided by K
(Example R = 1/2 (.50) divided by .43
R = 1.16)
FIGURE 12
FIREPLACE
FIREPLACE
HEARTH
HEARTH
FLOOR
FLOOR
20"
20"
12"
12"
METAL SAFETY STRIP
METAL SAFETY STRIP
WARNING:
THE HEARTH EXTENSION AND
THE GALVANIZED METAL STRIP
SHOULD BE INSTALLED ONLY IN
A HORIZONTAL RELATIONSHIP TO
THE FIREPLACE, AS ILLUSTRATED.
12"
12"
FLOOR LINE WITH 
FLOOR LINE WITH 
RAISED HEARTH
RAISED HEARTH
53D9032. Rev 1 03/03