Lennox Hearth EBVPFNM Outdoor Fireplace User Manual


 
7
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Periodically (After the Burning Season)
Maintenance Task Accomplishing Person Procedure
Cleaning Firebox Interior
Check Flame Patterns and Flame Height
Checking Vent System
Cleaning Glass Enclosure Panels
Homeowner
Homeowner
Homeowner
Homeowner
Carefully remove logs, vermiculite and black and
gray ceramic fiber chunks. Vacuum out interior of
the firebox. Clean firebox walls and log grate.
Replace logs, vermiculite and black and gray ce-
ramic fiber chunks as detailed on
page 9
.
Maintenance Task Accomplishing Person Procedure
Inspecting/Cleaning Burner, Logs
and Controls
Check Flame Patterns and Flame Height
Inspecting/Cleaning Pilot Burner and the Two
Main Burners
Checking Vent System
Appliance Checkout
Qualified Service Technician
Qualified Service Technician
Qualified Service Technician
Qualified Service Technician
Qualified Service Technician
Inspect valve and ensure it is properly operat-
ing. Check piping for leaks. Vacuum the con-
trol compartment, fireplace logs and burner
area.
Refer to
Figure 9 on page 9
and verify that the
flame pattern and height displayed by the
appliance conforms to the picture. Flames
must not impinge on the log set.
Refer to
Figure 11 on page 10 (SIT) or Figure 12
on page 10 (Honeywell)
. Remove any surface
build-up on pilot and burner assembly. Clean the
pilot nozzles, ignitor/flame rod and hood with a
soft brush. Ensure the pilot flame engulfs the
flame sensor as shown.
Inspect the vent system at the top and at the
base (within the firebox) for signs of blockage
or obstruction. Look for any signs of disloca-
tion of the vent components.
Perform the appropriate appliance checkout
procedure detailed in this manual.
Maintenance Schedule
Annually (Before the onset of the Burning Season)
Clean as necessary following the directions
provided in this manual. DO NOT TOUCH OR
CLEAN GLASS WHILE IT IS HOT.
Inspect the vent system at the top and at the
base (within the firebox) for signs of block-
age or obstruction. Look for any signs of
dislocation of the vent components.
Refer to
Figure 9 on page 9
and verify that
the flame pattern and height displayed by the
appliance conforms to the picture. Flames
must not impinge on the log set.