Lennox Hearth E260 Fire Pit User Manual


 
7
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Model F (1) G H J M
C260 22”
559mm
14”
356mm
22-1/2”
572mm
5-1/4”
133mm
50-1/2”
1283mm
E260 22”
559mm
14”
356mm
22-1/2”
572mm
5-3/4”
133mm
45”
1143mm
C260 with mantel
and/or side
shields u
22”
559mm
14”
356mm
22-1/2”
572mm
5-1/4”
133mm
38”
965mm
* Reduced clearances may be available for A, B, C and D
dimensions per NFPA 211 - latest edition, Standard for
Chimneys, Fireplaces, Vents, and Solid Fuel-Burning Appli-
ances (in Canada CSA B365 - latest edition). See section on
“Reduction of Appliance Clearance with Specified Forms of
Protection.”
** Side view of optional mantel deflector shown.
uElite™ E260 - Not tested for reduction of clearances
(1)Hearth extension reductions: 2” (51mm) reduction for 2”
(51mm) raised hearth. (USA) 16” minimum hearth exten-
sion on all stoves as measured from the door opening of the
unit. (Canada) 18”(450mm) minimum hearth extension on
all stoves as measured from the door opening of the unit.
Minimum distance of floor protection to the side = 8” (200mm).
This is measured from the sides of the door opening in the
USA and from the sides of the insert in Canada.
HeartH Protection
The hearth and/or floor protection must be a thermally rated
non-combustible hearth/floor protector meeting or exceeding
a thermal rating of k=.84 or equivalent with a listed thickness
of listed thickness of 3/4" (19mm) minimum in the USA and
Canada. The covering must extend USA-16”/Canada-18”
(C260) and 22” (E260) in front of the heater and 8” to the
side (measured from door opening in the USA and measured
from the side of the unit in Canada).
Top Facing / Trim
Side Facing Material
SIDE WALL
C
E (USA)
D
B
A
COMBUSTIBLE MANTEL
Insert
Maximum Mantel Depth = 9” (229 mm)
Hearth Protection
E (Canada)
M
6-1/2”
165mm
F
**
J
G
H
Mantel
Hearth Protection
Trim
Model *A *B *C *D E(1)
C260 30”
762mm
20”
508mm
20”
508mm
15”
381mm
8”
200mm
E260 23”
584mm
17”
432mm
20”
508mm
15”
381mm
8”
200mm
C260 with mantel
and/or side
shields u
30”
762mm
20”
508mm
20”
508mm
15”
381mm
8”
200mm
Notes
Facing material that projects more than 3/4” (19mm) from
the wall is considered a mantel or side wall.
MINIMUM FIREPLACE OPENING 22-1/2” (572mm) High x
28-1/2” (724mm)
required clearances
WARNING: BE ABSOLUTELY SURE THE DISTANCE BE-
TWEEN THE HEATER AND THE SURFACE OF ANY COM-
BUSTIBLE CONSTRUCTION IS NOT LESS THAN SHOWN
ON THIS PAGE.
Figure 4
Figure 5