KitchenAid KFGR271SSS Gas Grill User Manual


 
6
Built-In Installation Dimensions
(non-combustible enclosure)
IMPORTANT: If grill is to be installed in a combustible enclosure,
return this unit and replace it with the model which is
manufactured for use in a combustible enclosure.
Enclosure and clearance dimensions that are shown must be
used. Given dimensions provide required clearances.
The installation of this grill must conform with the current
standards CSA-Z21.58a-1998, or with local codes.
For installations in a non-combustible enclosure, the grill drops
into the opening and is supported by its side fl anges. Do not use
a bottom support.
Copies of the standards listed may be obtained from:
CSA International
8501 East Pleasant Valley Rd.
Cleveland, Ohio 44131-5575
Grill size A B
27” (68.6 cm) 26” (66.7 cm) 25-1/4” (64.1 cm)
36” (91.4 cm) 35” (89.5 cm) 34-1/4” (87.0 cm)
WARNING
Fire Hazard
Do not install this grill on or near combustible materials.
Doing so can result in death or fire.
Center or support
surfaces must be level
2
(5.1 cm)
minimum to
open hood
10-7/8
(27.0 cm)
1-1/8
(2.9 cm)
optional custom
access doors
B
19
(48.3 cm)
35-1/2
(90.2 cm)
6 (15.2 cm)
min. clearance
for rotisserie
22
(57.2 cm)
A
12
(30.5 cm)
minimum to
any accessory
2-1/4
(5.7 cm)
7-3/8
(18.7 cm)
Gas line
location at
rear of grill
Non-combustible enclosure installations
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
If codes permit and a separate ground wire is used, it is
recommended that a qualifi ed electrician determine that the
ground path is adequate.
Check with a qualifi ed electrician if you are not sure whether the
grill is properly grounded.
Do not ground to a gas pipe.
A 120-volt, 60-Hz, AC-only, 15-ampere, fused electrical supply is
required.
Recommended ground method
A grounded 3-prong outdoor outlet grounded in accordance with
the National Electrical Code ANSI/NFPA 70 or Canadian Electrical
Code (C22.1) — and local codes and ordinances.
Copies of the standards listed above may be obtained from:
CSA International
8501 East Pleasant Valley Rd.
Cleveland, Ohio 44131-5575
National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
3-prong polarized ground-
type outdoor outlet
3-prong ground
plug
power supply
cord
ground
prong
Electrical Requirements
Built-in models - rotisserie and grill light