ConversionToLPGas
This appliance isshipped from the factory equipped for use _.j, /
with Natural Gas. To convert it from Natural Gas for usewith
LP Gas, perform steps 1 through 4. lf2" OPENEND
WRENCH !
1. Remove natural gas odflce hoods. Install co}or coded _,=
orifice hoods supplied, located in a pack attached to the
outer plenum area of this appliance. (See Illustration "E" TURN
below, and LP Gas Conversion Instructions on page 6). CLOCKWISE
TOTIGHTEN
2. Invert cap in convertible appliance pressure regulator (if TURN
SOequipped) located at entrance to gas manifold. COUNTERCLOCKWISE
TOREMOVE ORIFICEHOOD
3. Adjust air shutters on individual burners for proper flame ILLUSTRATION "E"
appearance.
4, Adjust low flame setting at each burner by turning Control Settings
adjustment screw in center of valve stem.
The size and type of cookware and the amount and type of
To make these conversion adjustments follow the food being cooked will influence the setting needed for best
instructions and illustrations ("A" through "E" on cooking results. The setting indicated should serve as a
pages 3 - 4). guide whileyou become familiarwith your cooktop.
Use the HI flame setting to _ _
quickly bringfoods toa boilor
to begin a cooking operation.
Apply a non-corrosiveleak detection fluidto all joints and Then reduce to a lower
fittings in the gas connection between the supply line setting to continue cooking.
shut.off valve and the range. Include gas fittings and Neverleave foodunattended
joints in the range if connections were disturbed during over a HI flame setting, z
installation. Check for leaks! Bubbles appearing around
fittings and connections will indicate a leak. If a leak Med setting is used to
appears, turn off supply line gas shut-off valve and retest continue a cooking opera-
J for leaks. Never test for gas oaks with an open flame, tJon.Food will not cook any
faster when a HI flame
setting is used than that is
Thisapplianceis shippedfrom the factorywith orificehoods needed to maintain a gentle _
drilledforusewithNaturalGas. Toconvertfrom NaturalGas boil. Remember,water boils
toLP, apply a ll2" open-end wrenchto hexsectionof oriflce at the same temperature = "
hood. TURN COUNTERCLOCKWISE TO REMOVE. Save whether boiling gently or -_:
the Natural Gas orifice hoods just removed from this vigorously.
appliance for future use. Install color coded odfice hoods ,,._..,.
supplied. (See LP Gas Conversion Instructions above and Use Lo setting to keep food
page6).TURNCLOCKWISETOINSTALL, Holddimension at serving temperatures
specified in Illustration "E". without further cooking. You
may find that some cooking
may take place if the
cookware is covered. I
MinimumSpacingRequirement
ConvertibleGasCooktops . r
For installing a Double Bay Downdraft
Cooktop in combination with another
Downdraff Cooktop, the minimum spacing ;:
between adjacent units mustbe provided,as
shown, for satisfactory performance. :_
DOUBLE BAY DOUBLE BAY _!;