Jenn-Air JGD8345 Gas Grill User Manual


 
LowFlameAdjustment(SeeIllustration"C") PressureTesting
This appliance is shipped from the factory with low and The maximum gas supply pressure for the appliance
medium flame settings adjusted for usewith Natural Gas. If pressure regulator supplied on this appliance is 14" W.C.
further adjustment is necessary, or to readjust for usewith The test pressure for checking this appliance pressure
LP, proceed as follows: regulator must be at least 6" W.C. for Natural Gas, and at
least 11" W.C. for LP. It is shipped from the factory set for
1. Light burner and set control knob for low flame. Natural Gas at 5" W.C. output pressure.
2. Remove control knob from valve stem.
This appliance and its individual shutoff valve must be
disconnected from the gas supply pipingsystem during any
pressure testing ofthat system at test pressures in excess
of 1/2" PSIG (3.5 k Pa).
This appliance must be isolated from the gas supply piping
system by closing its individual manual shutoff valve during
any pressuretesting of the gas supply piping system at test
pressures equal to or less than 112"PSIG (3.5 k Pa).
3. Insert a slender, thin-blade screwdriver into the recessat
center of valve stem and engage blade with slot in
adjusting screw. AppliancePressureRegulatorConversion
4. Turn center stem adjusting screw to set flame size. (See Illustration "D")
clockwise to reduce. This unit is supplied with a Maxitrol Appliance Pressure
counterclockwise to increase. Regulator. Follow the instructions in illustration "D".
5. Replace control knobwhen adjustment is completed. MAXITROL APPLIANCE PRESSURE REGULATOR
Proper adjustment will produce a stable, steady blue flame APPLYDOWNW,_
of minimumsize. Thefinal adjustment should be checkedby FINGERPRESSUREAT DISCEDGESTO
turning knob from high to low several times without ___LP REPLACEPININCAP,[,,L
extinguishing the flame. CONVERTFR'_
CAP i
This adjustment, atlow setting, will automatically providethe _ AND PJN_,o' _j_ AIPDPLYARD
FINGER "
proper flame size at medium setting. NAT_ ,--r" NAT"T; PREEMoSSU_TOI
LP
' * ' FROMCAP
COUNTERCLOCKWISE TO _ Ii_ I_
i
INCREASE FLAMESIZE
CLOCKWISE
TO REDUCE
FLAME SIZE
VA'"___,-._,,,_i_._- ILLUSTRATION "D"
ILLUSTRATION "C"