Jenn-Air JGD8345 Gas Grill User Manual


 
InstallingCabinetryOverYourJenn.AirGrill
*A = 30" (76.2 ¢m) minimum vertical clearance between of local codes, with the latest edition of the National
cooking surfaceand construction above theappliance. Electrical Code ANSI/NFPA No. 70 USA or currant CSA
STANDARD C22.1 Canadian ElectricalCode part 1.
*B = 13" (33.02 cm) maximum depth of cabinets installed
above cooking top.
I Dottedlines
indicate
' rangehood
i construction
* To eliminate associated potential hazards such as
reaching over open flames, avoid use of cabinets above Cabinet Bottom
cooktop for storage space. Figure 2
CabinetsAboveCookingTop
Maximum depth of cabinets installed above cooking top is
13 inches.
CAUTION: SOME CABINETS AND BUILDING
MATERIALS ARE NOT DESIGNED TOWITHSTAND THE
HEAT PRODUCED BY THE NORMAL SAFE OPERATION
OF A LISTED APPLIANCE. DISCOLORATION OR
DAMAGE, SUCH AS DELAMINATION, MAY OCCUR.
InstallationOf Appliance
Followaccompanyingducting instructionscarefully.
This appliance isdesigned to always be vented outdoors. ConnectingApplianceToGasSupply
The Countertop Cutout, Cabinet Front Cutout and Duct A TRAINED SERVICEMAN OR GAS APPLIANCE
Openingshouldbe preparedaccordingto the illustrationon INSTALLER MUST MAKE THE GAS SUPPLY _ - ._
pages 1 and 2. CONNECTION. Leak testing of the appliance _1"_ . ''_
conducted by the installer according to the _ -7
The installationof this appliancemust conform with local instructions given.
codes or, in the absence of local codes, with the latest
editionof theNational FuelGas Code,ANSI Z223.1 USAor Installa manualshutoffvalve inanaccessiblelocationinthe
currentCAN/CGA-B149 )NSTALLATION CODE. gas lineexternalto thisapplianceforthe purposeofturning
on orshuttingoffgas to the appliance.
Theelectricalsupplyrequiredis110/120 Volt,A.C., 15amp,
60 Hz. This appliance is equipped with a grounded tpe Make the gas connection to the inlet to the appliance
power cord. A grounded outlet must be provided. It is pressure regulator on this appliancewith a 1/2" male p_pe
recommended, for convenience, this outlet be located inthe thread. Use an approved pipe joint compound resistant to
area shown in the shaded illustration (see figure 2). the action of LP gas at pipe connections.Test all joints for
gas leaks with a soap and water solution or other accepted
This appliance, when installed, must be electrically leakdetection means. Never test for gas leakswith an opeIT" .. ::
groundedin accordance with local codes or, in the absence flame....