Hearth and Home Technologies GO30MTCH Outdoor Fireplace User Manual


 
Hearth & Home Technologies • Grand Oak Match Light Gas Log Sets • 4004-300 Rev C • 12/05
13
O. Inspect the Venting System
The fi replace venting system is designed and constructed to
develop a positive fl ow adequate to remove fl ue gases to the
outside atmosphere. See fi replace installation instructions.
Possible cures if spilling occurs:
The damper needs to be opened further.
The fi replace opening needs to be reduced by adding a
drop panel across the top under the lintel.
The air supply from outdoors needs to be increased. Open
the outside air kit if the appliance is so equipped, or crack
open a door or window.
If necessary, seek expert advice. Do not operate this
appliance.
Cleaning
Periodic examination and cleaning of the venting system
of the fi replace should be done before initial use and at
least annually by a qualifi ed agency.
A spillage test must be made before the installed
appliance is left with the consumer.
Close all doors and windows in the home.
Light the log set (see Lighting Instructions).
After three minutes, test with a smoke match, smoke
candle, stick incense or cigarette 1 in. below the top of
the opening (lintel) moving across the full width. If spillage
(smoke down into the room) occurs, it will most likely be
near the top, outside corners.