Grand Hall 89795 Fire Pit User Manual


 
IMPORTANT; Your Homestead patio fireplace cannot
be converted to use Natural Gas. Attempting to do so is
extremely hazardous and wilt also void the warranty.
Correct LP Gas Tank Use
The patio fireplace isdesigned for use with a standard
20 lb. Liquid Propane Gas (LP Gas) tank, not included in
box. Never connect your fireplace to an LP gas tank
directly without regulator that exceeds this capacity. A
tank of approximately 12 inches in diameter by 18-1/2
inches high is the maximum size LP gas tank to use. You
must use an "OPD" gas tank which offers a listed
Overfill Protection Device. This safety feature
prevents tank from being overfilled which can cause
malfunction of LP gas tank, regulator and/or fireplace.
The LP gas tank must be connected and marked in
accordance with the specification for LP-gas cylinders
of the U.S. Department of Transportation (D.O.T) or the
National Standards of Canada, CAN/CSA-B339,
Cylinder, Spheres and Tubes for Transportation of
Dangerous Goods, and Commission, as applicable.
1. The LP gas tank has a shutoffvalve, terminating in an
LP gas supply tank valve outlet, that is compatible with
type 1 tank connection device. The LP gas tank must
also have a safety relief device that has a direct
connection with the vapor space of the tank.
2. The tank supply system must be arranged for vapor
withdrawal.
3. The LP gas tank used must have a collar to protect the
tankvalve.
This patio fireplace isnot intended to be installed in or on
recreational vehicles and!or boats.
Never connect an unregulated LP gas tank to your
fireplace. The gas regulator assembly supplied with
your fireplace is adjusted to have an outlet pressure
of 11" water column(W.C.) for connection to an LP
gas tank.
Only use the regulator with hose assembly supplied
with your fireplace. Replacement regulator with
hose assembly must be those specified by
manufacturer.
Have your LP gas tank filled by a reputable propane
gas dealer and visually inspected and re-qualified at
each filling.
Never fill the gas tank beyond 80 percent full. Have
your propane gas dealer check the release valve
after every filling to ensure that it remains free of
defects.
Always keep LP gas tanks in upright position. Do not
store(or use) gasoline or other flammable vapors
and liquids in vicinity of this fireplace.
LP gas tanks not connected for use must NOT be
stored inside of fireplace or in the vicinity of this or
any other gas appliance.
Do not subject the LP gas tank to excessive heat.
Never store an LP gas tank in the garage or other
indoor location. Always disconnect the LP gas tank
first and store it safety outside.
LP gas tanks must be stored outdoors in a well-
ventilated area and out of the reach of children.
Disconnected LP gas tanks must not be stored in a
building, garage or any other enclosed area.
When your fireplace is not in use the gas must be
turned off at the gas tank.
The regulator with hose assembly can be seen
when you open the doors. It should be inspected
before each use of the fireplace. If there is
excessive wear or any abrasions, or if the hose is
cut, it must be replaced prior to the fireplace being
used.
Keep the gas regulator hose away from hot surface.
Avoid unnecessary twisting of hose. Visually
inspect hose prior to each use for cuts, cracks,
excessive wear or other damage. If the hose
appears damaged do not use the fireplace. Call
1-888-317-7642 for an authorized replacement
hose.
Never allow children to play near your fireplace.
4