Grand Hall 89795 Fire Pit User Manual


 
Congratulations
Your LP Patio Fireplace is now ready for use. Before the first use and at the beginning of each season (and
whenever the LP gas tank has been changed):
1. Read all safety, Lighting and operating instructions.
2. CheckGasValveOdfices, BumerTubeforanyobstructions.
3. Perform gasleakcheckaccording toinstructionsfound on page 11ofthis manual.
Never test for leaks with a flame. Prior to the first use, at
the beginning of each season, or every time your LP gas
tank is changed, you must check for gas leaks. Follow
these four steps;
1. Make a soap solution by mixing one part liquid
detergent and one part water.
2. Make sure the status of heater is off, then turn the
gas ON at source.
3. Apply the soap solution to all gas connections,
especially apply to Inlet/manifold pressure tap
on the gas valve after reading the pressure.
Bubbles will appear in the soap solution if
connections are not properly sealed. Tighten or
repair as necessary.
If you have a gas leak that you cannot repair, turn off
the gas at the source, disconnect fuel line from your
fireplace and call 1-888-317-7642 for repair
assistance.
4. Do not attempt to light the automatic pilot by hand
(match, cigarette, lighter etc.)
mm
WARNING: THESE PROCEDURES MUST BE
PERFORMED BY QUALIFIED INSTALLER,
SERVICEAGENCYORTHE GAS SUPPLIER.
1. Manifold pressure and Inlet pressure can be
checked by applying an 1/4" rubber hose to the
protruding outlet tap on the combination valve.
2. Loosen the small screw 2 to 3 turns counter-
clockwise.
3. Connect the 1/4" rubber hose to outlet gas pressure
tap with manometer.
4. Read the pressure on the Manometer.
5. Seal tap afterwards by tightening the small screw.
Rubber Hose
Outlet gas pressure tap
_,,. _..GAS
Se_o moor
Inlet gas pressure tap
Note : At first use the housing may emit a slight odor
and smoke due to the burn off of oil used in the
manufacturing process. This is to be expected.
1. Famitiadzeyourselfwith the safety instructionsand
warnings at the front of this manual. Do not smoke
while lighting the fireplace or checking gas supply
connections. Be sure your fireplace is installed in
accordance with the minimum clearance from
combustibles as shown on page 3 of this manual.
2. Make sure ait connections are securely tightened.
A. Turning the fireplace ON
Open Door and slowly open valve on gas tank.
Press the ON/OFF button to operate the fireplace. The
Status indicator light will illuminate green. Refer to Fig. 1.
After approximately 5 seconds the automatic spark will
light the burner and the status indicator light will
illuminate red after detecting the flame by micro-
processor.
Notes: If the fireplace does not ignite on the initial try,
the spark will stop and the indicator light wilt blink two
times.
To attempt to re-ignite press the ON!OFF button again to
cancel the error condition. Then press the ON/OFF
button again to operate.
Your fireplace will not operate when the error message
is indicated. This process may need to be repeated
several times on the initial start up because of air in the
LP supply line and whenever a 20 lb LPG tank is
replaced or if the gas line is disconnected from the
fireplace for any reason.
The status indicator light will turn off after approximately
30 seconds to save battery power.
Fig. 1
UP Button /OFF Button
Status indic
DOWN But
To adjust the burning level:
Press UP or DW button to adjust the burning level to
maximum, middle and minimum level.
11