Grand Hall 89795 Fire Pit User Manual


 
//_ WARNING
(a) Do not store a spare LP-gas cylinder near this
fireplace.
(b) Never fill the cylinder beyond 80 percent full.
(c) Ifthe information in"(a)" and "(b)" is not followed
exactly, a fire causing death or serious injury may
occur.
FOR YOUR SAFETY
1. Do not store or use gasoline or other flammable
material and liquids in the vicinity of this fireplace or
other appliance.
2. ALP cylinder not connected for use must not be
stored inthe vicinity of this or any other appliance.
IMPORTANT; This fireplace is only for use with LP
type of gas as equipped from the manufacturer and
is not convertible for use with other gases.
IMPORTANT; This fireplace may not be used for
preparing food. Gases and/or food particles may fall
into the appliance and inhibit proper operation.
Important safety rules:
YOUNG CHILDREN should be carefully
supervised when they are in the area of the
fireplace.
NEVER hang anything including clothes or
other flammable items on the fireplace.
The screens installed in this fireplace must be in
place at all times when in operation to prevent
foreign objects from entering the unit.
For proper ventilation around the unit, do not
obstruct the upper and lower vent louvers.
The fireplace should be inspected before first
use and at least annually by a qualified service
person. More frequent cleaning may be required
depending on area conditions.
Keep burner and control compartment clean.
See installation and operating instructions.
1 Clearance from combustibles:
Proper clearance from combustible materials must
be maintained at all times (See Fig 1 for minimum
clearance)
Combustible materials include wood, compressed
paper, plant fibers, plastic, plexiglass or other
materials capable of being ignited and burned.
Such materials shall be considered combustible
even though flameproof, fire-retardant treated or
plastered. Additional clearance may be required for
glass, painted surfaces and other materials which
may be damaged by radiant or convection heat.
Unit to walls: 24 Inches
Unit to ceiling: 24 Inches
Fig 1 Minimum clearance from combustibles.
24inches
2. The gas inlet supply and normal operating manifold
pressure for fireplace is as follows. For gas supply
line pressures in excess of 14 "W.C., consult with
your representative or the factory.
Type of Gas Liquid Propane
Maximum inlet pressure 14 "W.C.
Minimum inlet pressure 11 "W.C.
Manifold pressure 9 "W.C.
Gas Rating 41,000 BTU/hr
3. The fireplace must be inspected before each use
and annually by a qualified service person.
AIt gas connections should be checked for leaks
utilizing a soap solution. Never use a flame for
this purpose.
The flame pattern should be visually checked
whenever the fireplace isoperated.
Yourfireplace area must be kept clear and free of
combustible materials, gasoline and other
flammable vapors and liquids.
Clean your fireplace only with noncombustible,
non-corrosive cleaning agents.
4. Your fireplace has been designed with several safety
features as follows.
A thermal fuse for overheating cut-off protection.
Flame failure shut off.
Automatic ignition.
Safety combination valve shut off.
The operating condition is controlled and
diagnosed by a micro processor.
The micro processor is an advanced feature which also
makes it easy for one touch operation with remote
control or manual push button.
Any modification to the fireplace not described in the
installation instructions may compromise the safety of
this fireplace and will void the warranty.
3