GE Monogram Professional Outdoor Grills and Cooktop Gas Grill User Manual


 
Installation
LP GAS GRILL CONNECTIONS TO A GRILL OR COOKTOP
LP gas connections
• Completely close the main valve on the LP tank
supplying the grill.
• Attach one hose to the cooktop gas inlet; tighten.
• Attach one hose to the grill gas inlet; tighten.
• Attach the hose ends from the grill and cooktop to
the ends of the supplied 3/8” flare tee as shown.
• Attach the supplied regulator hose assembly to
the 3/8” flare tee as shown.
16
LP TANK TIE-DOWN (for built-in island installations)
Outdoor cooking applicances require an integral
means of limiting the movement of the LP gas cylinder.
For built-in appliances which require the use of a
remote LP gas supply cylinder (island applications), a
retaining device must be created.
Lateral movement shall not exceed 1" (25.4 mm) at the
retention means. The cylinder, or any portion of, shall
not become dislodged from the retention device when
a lateral force of equal weight to the cylinder is
applied, from any direction, at the center of the vertical
height of the cylinder.
Retaining device must not interfere with the operation
of the cylinder valve, and no movement shall transmit
strain to rigid tubing or pipe/hose connections. Hose
must not touch any portion of the grill/appliance. (ANSI
Z21 58z 2006/CGA 1.6z 2006)
8-1/4"
8-1/4"
1" Min.
Tee Nut 1/4-20
Recommended
(3 Sides of Frame)
LP tank is inserted into frame.
LP tank is secured with fixed
thumbscrew on three sides.
Thumbscrew 1/4-20
right angle or spaded
2
"
long (3 required)
TANK DRAWER WITH LP TANK RETAINER LOOP (free-standing models only)
To install the LP tank, fully extend the tank drawer
and the lift retainer loop. Place the tank on the
drawer bottom, inserting the loop on the bottom of
the tank through the hole in the drawer bottom. Tilt
the tank forward to lower the retainer loop to
engage the top ring on the tank. Insert the coupler
sleeve on the regulator over the tank inlet; turn
clockwise to tighten. Do not overtighten the coupler.
Open the tank valve when ready to use the grill.
Always close the tank valve when cooking is
complete.
LP Gas Cooktop and Grill Combination
Connections
Use this method to connect a single tank to both
appliances.
To Cooktop
3/8" Flare Tee
From Regulated
LP Tank
To Manifold
of Grill
Note: The supplied hoses are
different lengths. Connect them to
suit your installation situation.