Frigidaire Electric Patio Grill Electric Grill User Manual


 
L.P. Gas Installation
Frigidaire Gas Grills that are set to operate with L.P. gas come with a high capacity hose and regulator
assembly. (Note: Only use the pressure regulator and hose assembly supplied with the grill or a
replacement pressure regulator and hose assemblies specified by Frigidaire). This assembly is designed
to connect directly to a standard 20 lb. L.P. cylinder.
Attach the gas hose assembly to the brass 3/8 flared fitting using an adjustable wrench on the under side of the
grill. Tighten securely and attach other end to the propane tank. (sold separately) (See Fig. 24)
L.P
. Tank Information
Never use a dented or rusted L.P. tank or cylinder with a damaged valve.
The L.P. cylinder must be provided with a shut-off valve terminating in an L.P. gas supply cylinder outlet
specified, as applicable, for connection No. 510 in the standard for compressed gas cylinder valve outlet and
inlet connection ANSI/CGA-V-1. Cylinders must not be stored in a building, garage, or any other enclosed
area. (The L.P. cylinder must have an overfill protection device, OPD, on it.)
The L.P. Gas supply cylinder must be constructed and marked in accordance with the specifications for L.P.
gas cylinders of the U.S. Department of Transportation (DOT) or the National Standard of Canada,
CAN/CAS-B339, “Cylinders, Spheres and Tubes for the Transportation of Dangerous Goods.”
•When not in use, gas supply cylinder valve is to be in the “OFF” position.
•The tank supply system must be arranged for vapor withdrawal. (LP Tank must be kept in an upright
position.)
•The regulator and hose assembly must be inspected before each use of the grill. If there is excessive abrasion
or wear or if the hose is cut, it must be replaced prior to the grill being used again.
•Cylinders must be stored outdoors out of the reach of children and must not be stored in a building, garage or
any other enclosed area.
•Never fill the cylinder beyond 80% full
•Do not store a spare LP-gas cylinder under or near this appliance
14
Fig. 24
LP hose/
regulator
supplied
with grill.
(Type 1
connector)
Gas Requirements