Enviro C-10100 Fire Pit User Manual


 
Adjust pilot if necessary.
Make sure pilot flame engulfs
the thermopile and does
“NOT” have a yellow
luminous flame.
SEE PAGE 4 FIGURE 4.
4) MAIN BURNERS WILL
NOT STAY LIT
Check outlet gas pressure.
Check for clogged pilot
injector or blocked air inlet.
Using a multimeter check
thermopile. If not constant
replace thermopile.
Make sure millivolt readings
from thermopile are constant.
Make sure all wiring is not
damaged or broken and all
connections are tight.
Correct if necessary.
By pas spill switch.
If unit starts, replace spill
switch.
B-VENTED MODELS
Check spill switch.
Check to make sure the vent is
drafting properly.
Check for spillage.
SEE PAGE 12.
Make sure all venting meets
manufactures specifications
as well as local gas and
building code requirements.
Correct if necessary.
Check chimney for blockage
or restriction.
Correct if necessary.
Sherwood Industries Ltd. ENVIRO PAGE 11