When leak checks are complete, turn gas supply OFF at the source and rinse
connections with water.
Check:
1) Side burner hose to side burner valve.
2) Gas supply hose-to-manifold connection.
ƽ WARNING: If there is a leak at connection (1) or (2), retighten
the fitting with a wrench and recheck for leaks with soap and
water solution. If a leak persists after retightening the fitting,
turn OFF the gas. DO NOT OPERATE THE GRILL. Contact
the Customer Service Representative in your area by calling
1-800-382-2637.
3) Regulator-to-Cylinder connection.
4) The hose-to-regulator connection.
5) Valves-to-manifold connections.
ƽ WARNING: If there is a leak at connections (3), (4) or (5),
turn OFF the gas. DO NOT OPERATE THE GRILL. Contact
the Customer Service Representative in your area by calling
1-800-382-2637.
When leak checks are complete, turn gas supply OFF at the source and rinse
connections with water.
Re-install Control Panel
Follow ‘Remove Control Panel’ steps in reverse. Make sure all screws are secure.
Breaking in Your Grill
When fi ring your grill for the fi rst time, it is advisable to run the Main Burner(s) on
“HI” for 20 minutes with the hood down and then turn the Main Burners “OFF”. This
tempers the grill.
Lighting Your Grill
ƽ WARNING: Before each use of your grill it is important to
inspect the full length of the gas line hose. If it is evident
there is excessive abrasion or wear, or the hose is cut, the
hose must be replaced prior to the appliance being put into
operation.
ƽ DANGER: When the “excess gas flow control” feature is
activated, a small amount of gas is still flowing to the
burners. After turning OFF the cylinder valve, wait at least
5 minutes for the gas to clear before attempting to light
the barbecue. Failure to do so may result in an explosive
flame-up, which can cause serious bodily injury or death.
ƽ DANGER: Make sure that the lid is in the full open postion
any time you attempt to light your grill. Failure to open the
lid could lead to delayed ignition which may result in serious
bodily injury or death, or in a fire or an explosion causing
damage to property.
ƽ WARNING: The burner control knobs must be in the OFF
position before turning on the liquid propane cylinder tank
valve. If they are not in the OFF position, when you turn on
the LP cylinder valve, the “excess gas flow control” feature
will activate, limiting the flow from the LP cylinder. If this
should occur, turn off the LP cylinder valve and burner
control knobs. Start over.
Check your parts list or your authorized dealer for the proper replacement hose
assembly. For base cabinet model grills, it will be necessary to go behind your grill to
check the hose.
3200/4200
CONNECTION
CONNECTION
Liquid Propane Gas Grills
Liquid Propane Gas Grills
NORMAL OPERATION
NORMAL OPERATION