7. Turn equipment shutoff valve counter-
clockwise to the ON position.
Do not force.
8. Close lower louver panel.
9. Turn on all electric power to the appli-
ance.
10. Turn the wall switch to the ON position.
11. Visually locate the pilot. The ignitor should
begin to spark and the main burner should
igniteonceameappearsatpilot.
•Iflightingtheapplianceforthersttime
each season, it may take several attempts
before the supply gas can reach the pilot
and main burners.
• If the appliance will not stay lit after sev-
eral attempts, follow the instructions To
Turn Off Gas To Appliance and call your
service technician or gas supplier.
Figure 48 - Turning Equipment Shutoff
Valve to the OFF Position
Equipment
Shutoff Valve
Pilot Adjustment Screw
OPERATING FIREPLACE
Continued
TO TURN OFF GAS
TO APPLIANCE
1. Turn off the wall switch.
2. Turn off all electric power to the appliance
if service is to be performed.
3. Open lower louver panel.
4. Remove front hearth brick and control
access panel.
5. Turn equipment shutoff valve clockwise
to OFF. Do not force.
6. Close lower louver panel.
Figure 49 - Pilot
Sensing
Rod
Pilot Burner
Ignitor
OPTIONAL REMOTE
OPERATION
Note: The WRC receiver and hand-held re-
mote control kit must be purchased separately
(see Accessories, page 33). Follow installation
instructions on page 25.
1. Turn equipment shutoff valve to ON position.
You can now turn the burner on and off with
the hand-held remote control unit.
IMPORTANT: Be sure to press the ON/OFF
buttons on the hand-held remote control
unit for up to 3 seconds to assure proper
operation.
2. Press the ON/OFF button to turn the
burner on and off.
OPERATING OPTIONAL
BLOWER ACCESSORY
Locate the blower controls by opening the lower
louverpanelonthereplace.Blowercontrols
are located on the left side of the switch bracket
to the right just inside the louver panel.
The BK manual blower and the BKT thermo-
statically-controlled blower have an ON setting
and an OFF setting. The blower will only run
when the switch is in the ON position. In the
OFF position, the blower will not operate.
Note for BKT Only: If you are using BKT
blower with optional thermostat (wall mounted
orremotecontrol)forthereplace,yourre-
place and blower will not turn on and off at the
sametime.Thereplacemayrunforseveral
minutes before the blower turns on. After the
heater modulates to the pilot position, the blow-
er will continue to run. The blower will shut off
afterthereboxtemperaturedecreases.
The blower helps distribute heated air from
thereplace.Periodicallycheckthelouversof
thereboxandremoveanydust,dirtorother
obstructionsthatwillhindertheowofair.