Desa VSGF33NRC Outdoor Fireplace User Manual


 
www.desatech.com
119304-01A4
SAFETY INFORMATION
Continued
6. Do not add extra logs or ornaments such as
pine cones, vermiculite, or rock wool. Using
these added items can cause sooting. Do not
add lava rock around base. Rock and debris
could fall into the control area of replace.
7. To prevent the creation of soot, follow the
instructions in Cleaning and Maintenance,
page 21.
8. Before using furniture polish, wax, carpet
cleaner, or similar products, turn heater off.
If heated, the vapors from these products may
create a white powder residue within burner
box or on adjacent walls or furniture.
9. This replace needs fresh air ventilation to run
properly. This replace has an Oxygen Deple-
tion Sensing (ODS) safety shutoff system. The
ODS shuts down the replace if enough fresh
air is not available. See Air for Combustion and
Ventilation, page 5. If replace keeps shutting
off, see Troubleshooting, page 23.
10. Do not run replace
• where ammable liquids or vapors are used
or stored
• under dusty conditions
11. Do not use this replace to cook food or burn
paper or other objects.
12. Do not use replace if any part has been exposed
to or under water. Immediately call a qualied
service technician to inspect the replace and to
replace any part of the control system and any
gas control which has been under water.
13. Do not operate replace if any log is broken.
Do not operate replace if a log is chipped
(dime-sized or larger).
14. Turn replace off and let cool before servicing.
Only a qualied service person should service
and repair replace.
15. Operating replace above elevations of 4,500
feet could cause pilot outage.
16. To prevent performance problems in
propane/LP units, do not use propane/LP
fuel tanks of less than 100 lbs. capacity
(propane/LP units only).
17. Provide adequate clearances around air
openings.
PRODUCT
IDENTIFICATION
Figure 1 - Log Base Assembly
Optional
Blower
Assembly
(Not
Included)
Top Louver
Assembly
Fireplace
Hood
Bottom
Louver
Assembly
Screen
Assembly
Top Outer Casing
Firebox
Support
Figure 2 - Fireplace
LOCAL CODES
Install and use replace with care. Follow all local
codes. In the absence of local codes, use the lat-
est edition of The National Fuel Gas Code ANSI
Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
Note: Where listed vented decorative logs are
required, thermostat operation is not permitted.
Optional
Remote
Control
Log Set
Base
Assembly
Front
Burner
Rear
Burner