Desa (V)K42P SERIES Outdoor Fireplace User Manual


 
111921-01D
For more information, visit www.desatech.com
For more information, visit www.desatech.com
24
OPERATING FIREPLACE
WARNING: If you do not follow these instructions
exactly, a fire or explosion may result causing prop-
erty damage, personal injury or loss of life.
A. This appliance has a pilot which must be lighted by hand.
When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area
for gas. Be sure to smell next to the floor because some gas
is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electric switch; do not use any phone
in your building.
Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
C. Use only your hand to push in or turn the gas control knob.
Never use tools. If the knob will not push in or turn by hand,
don't try to repair it, call a qualified service technician. Force
or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect
the appliance and to replace any part of the control system
and any gas control which has been under water.
FOR YOUR SAFETY READ
BEFORE LIGHTING
LIGHTING
INSTRUCTIONS
1. STOP! Read the safety information above.
2. Open lower louver panel.
3. Turn off all electric power to the fireplace.
4. Push in gas control knob slightly and turn clockwise
to “OFF”.
5. Wait five (5) minutes to clear out any gas. Then smell for
gas, including near the floor. If you smell gas, STOP! Fol-
low “B” in the safety information above. If you don't smell
gas, go to the next step.
6. The pilot is located by the main burner and should not re-
quire accessing for lighting.
7. Turn gas control knob counterclockwise to “PILOT”.
8. Push in gas control knob all the way and hold. Immedi-
ately light the pilot by repeatedly depressing the piezo spark
ignitor until a flame appears. Continue to hold for about
one (1) minute after the pilot is lit. Release gas control knob
and it will pop back. Pilot should remain lit. If it goes out,
repeat steps 5 through 8.
If gas control knob does not pop up when released, stop
and immediately call your service technician or gas supplier.
If the pilot will not stay lit after several tries, turn the
gas control knob to “OFF” and call your service techni-
cian or gas supplier.
9. Turn on all electric power to the fireplace.
10. Turn gas control knob counterclockwise to “ON”.
11. This valve is equipped with a HI/LO feature. Set fireplace
input as desired.
12. Close lower louver panel.
OPERATING FIREPLACE
For Your Safety Read Before Lighting
Lighting Instructions
To Turn Off Gas To Appliance
Manual Lighting Procedure
TO TURN OFF GAS
TO APPLIANCE
1. Open lower louver panel.
2. Set selector switch in the OFF position to prevent draining
battery.
3. Turn off all electrical power to the appliance if service is to
be performed.
4. Push in gas control knob slightly and turn clockwise
to “OFF”.
5. Close lower louver panel.
Shutting Off Burners Only (pilot stays lit)
You may shut off the burners and keep the pilot lit by doing one
of the following:
1. Turn gas control knob clockwise to the PILOT po-
sition.
2. Set selector switch in the OFF position.
MANUAL LIGHTING
PROCEDURE
1. Remove glass door (see Removing/Replacing Glass Door,
page 21.)
2. Follow steps 1 through 8 under Lighting Instructions.
3. Depress gas control knob and light pilot with match.
4. Keep gas control knob pressed in for 30 seconds after light-
ing pilot. After 30 seconds, release gas control knob. Fol-
low steps 10 through 14 under Lighting Instructions.
5. Replace glass door (see Removing/Replacing Glass Door,
page 21).
O
F
F
P
I
L
O
T
O
N
L
O
I
H
Figure 50 - Control Valve
Piezo
Ignitor
Gas Control
Knob
Variable Control Knob