VENTING INSTALLATION
INSTRUCTIONS
Continued
Vertical Venting
V = 40' max.
Figure 24 - Vertical Venting Configuration With No Horizontal
Run (Vertical Round High Wind Termination Shown)
Note:
Install restrictor
into inner collar of
fireplace as shown.
45° Elbow
HIGH ALTITUDE INSTALLATION
Your DESA direct-vent fireplace has been tested and approved for
elevations from 0-2000 feet (USA) and elevations from 0-4500 feet
(Canada).
When installing this fireplace at an elevation above 2000 feet (in the USA),
you may need to decrease the input rating by changing the existing burner
orifice to a smaller size. Reduce input 4% for each 1000 feet above sea level.
Check with your local gas company for proper orifice size identification.
When installing this fireplace at an elevation above 4500 feet (in
Canada), check with local authorities.
Consult your local gas company to help determine the proper orifice
for your location.
For assistance with any high altitude installation contact DESA’s
Customer Service Department at 1-866-672-6040.
VENTING INSTALLATION INSTRUCTIONS
Installation for Vertical Termination (Cont.)
High Altitude Installation
Parts Lists for Venting Kits and Components
PARTS LISTS FOR VENTING KITS AND COMPONENTS
DESA (5/8") Pipe & Vent Kits
Number Description
P58-6 6" Section Double Wall Pipe, Galvanized
P58-12 12" Section Double Wall Pipe, Galvanized
P58-24 24" Section Double Wall Pipe, Galvanized
P58-36 36" Section Double Wall Pipe, Galvanized
P58-48 48" Section Double Wall Pipe, Galvanized
PA58-712 Adjustable 7"-12" Section Double Wall Pipe, Galvanized
FPA58-6 6" Duravent Collar to FMI Pipe Adaptor (6" Collar/Pipe
Section)
DPA58-6 6" FMI Collar to Pipe Duravent Adaptor (6" Collar/Pipe
Section)
E58-45 45° Elbow, Galvanized
E58-90 90° Elbow, Galvanized
FSE58-45 45° Starter Elbow, Galvanized (Duravent Collar to
FMI Pipe)
DSE58-45 45° Starter Elbow, Galvanized (FMI Collar to Duravent
Pipe)
VKG-58 Ground Floor Vent Kit
VKB-58 Basement Vent Kit
VKS-58 Snorkel Vent Kit
VKR-58 Roof Vent Kit
VKC-58 Corner Vent Kit
HTK Horizontal Round Termination Kit
HT-58 Horizontal Round Termination, Galvanized
HTKS-58 Horizontal Square Termination Kit
HTS-58 Horizontal Square Termination, Galvanized
VT-58 Vertical Round Termination, Galvanized
ST-58-14 14" Snorkel Termination, Galvanized
ST-58-36 36" Snorkel Termination, Galvanized
SC-58 Storm Collar, Galvanized
WF-58 Wall Firestop, Galvanized
RF-58-6 Roof Flashing - 0 to 6/12 Pitch, Galvanized
RF-58-12 Roof Flashing - 6/12 to 12/12 Pitch, Galvanized
VR-58 Vertical Restrictor, Galvanized
S-58 Vinyl Siding Standoff, Galvanized
WS-58 Wall Strap
CS-58 Cathedral Ceiling Support
FP-58 Firestop Plate
SF-58 Stucco Flashing - For use with HTS-5