Desa VDCFTPB Outdoor Fireplace User Manual


 
www.desatech.com
116526-01B30

1. Control knob not fully pressed
in
2. Control knob not pressed in
long enough
3. Safety interlock system has
been triggered
4. Equipment shutoff valve not
fully open
5. Pilot ame not touching ther-
mocouple, which allows ther-
mocouple to cool, causing
pilot flame to go out. This
problem could be caused by
one or both of the following:
A) Low gas pressure
B) Dirty or partially clogged
ODS/pilot
6. Thermocouple connection
loose at control valve
7. Thermocouple damaged
8. Control valve damaged
1. Inlet gas pressure is too low
2. Burner orice is clogged
3. Thermopile leads disconnected
or improperly connected (Re-
mote-Ready Models Only)
4. Burners will not come on in re-
mote position (Remote-Ready
Models Only)
1. Manifold pressure is too low
2. Burner orice is clogged
1. Burner orice is clogged or
damaged
2. Damaged burner
3. Gas regulator defective
4. Inlet gas pressure is too low
REMEDY
1. Press in control knob fully
2. After ODS/pilot lights, keep
control knob pressed in 30
seconds
3. Wait one minute for safety in-
terlock system to reset. Repeat
ignition operation
4. Fully open equipment shutoff
valve
5. A) Contact local natural or
propane/LP gas company
B) Clean ODS/pilot (see
Cleaning and Maintenance,
page 27) or replace ODS/pilot
assembly
6. Hand tighten until snug, then
tighten 1/4 turn more
7. Replace pilot assembly
8. Replace control valve
1. Contact local natural or pro-
pane/LP gas company
2. Clean burner (see Cleaning
and Maintenance, page 27)
or replace burner orice
3. Reconnect leads (see Wiring
Diagram, page 28)
4. Replace battery in transmitter
and receiver
1. Contact local natural or pro-
pane/LP gas company
2. Clean burner (see Cleaning
and Maintenance, page 27)
or replace burner orice
1. Clean burner (see Cleaning
and Maintenance, page 27)
or replace burner orice
2. Replace damaged burner
3. Replace gas regulator
4. Contact local natural or pro-
pane/LP gas company

ODS/pilot lights but flame
goes out when control knob is
released
Burner does not light after
ODS/pilot is lit
Delayed ignition of burner
Burner backring during com-
bustion
TROUBLESHOOTING
Continued