Desa VDCFTPB Outdoor Fireplace User Manual


 
www.desatech.com
116526-01B 27
INSPECTING BURNERS
Check pilot ame pattern and burner ame pat-
terns often.

Figure 45 shows a correct pilot ame pattern.
Figure 46 shows an incorrect pilot ame pattern.
The incorrect pilot ame is not touching the ther-
mocouple. This will cause the thermocouple to
cool. When the thermocouple cools, the replace
will shut down.
If pilot ame pattern is incorrect, as shown in
Figure 46
turn replace off (see To Turn Off Gas to Appli-
ance, page 22 for Thermostat-Controlled Mod-
els or page 24 for Remote-Ready Models)
see Troubleshooting, page 29
Note: The pilot ame on natural gas units will
have a slight curve, but ame should be blue and
have no yellow or orange color.
Figure 45 - Correct Pilot Flame Pattern
(Propane/LP Remote-Ready Shown)
Pilot Burner
Thermocouple
Figure 46 - Incorrect Pilot Flame Pattern
(Propane/LP Remote-Ready Shown)
Pilot Burner
Thermocouple

Figure 47 shows a correct burner ame pattern.
Figure 48 shows an incorrect burner ame pattern.
The incorrect burner ame pattern shows sporadic,
irregular ame tipping. The ame should not be
dark or have an orange/reddish tinge.
Note: When using the replace the rst time, the
ame will be orange for approximately one hour
until the log cures.
If burner ame pattern is incorrect, as shown in
Figure 48
turn replace off (see To Turn Off Gas to Appli-
ance, page 22 for Thermostat-Controlled Mod-
els or page 24 for Remote-Ready Models)
see Troubleshooting, page 29
Figure 47 - Correct Burner Flame Pattern
Figure 48 - Incorrect Burner Flame
Pattern
CLEANING AND
MAINTENANCE


CAUTION: You must keep
control areas, burner and cir-
   
   
    
   
    
   
 
   

WARNING: Failure to keep
    


BURNER INjECTOR HOLDER AND

The primary air inlet holes allow the proper
amount of air to mix with the gas. This provides
a clean burning ame. Keep these holes clear of
dust, dirt, lint and pet hair. Clean these air inlet
holes prior to each heating season. Blocked air
holes will create soot. We recommend that you
clean the unit every three months during operation
and have replace inspected yearly by a qualied
service person.