Desa VDCFRPB Outdoor Fireplace User Manual


 
www.desatech.com
116526-01B4
SAFETY INFORMATION
Continued
1. This appliance is only for use with the type
of gas indicated on the rating plate. This ap-
pliance is not convertible for use with other
gases.
2. Do not place propane/LP supply tank(s) in-
side any structure. Locate propane/LP supply
tank(s) outdoors.
3. If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not use
any phone in your building
• immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions
• if you cannot reach your gas supplier, call
the re department
4. This replace shall not be installed in a bed-
room or bathroom.
5. Do not use this replace as a wood-burning
replace. Use only the logs provided with
the replace.
6. Do not add extra logs or ornaments such as
pine cones, vermiculite or rock wool. Using
these added items can cause sooting. Do not
add lava rock around base. Rock and debris
could fall into the control area of replace.
7. This replace is designed to be smokeless.
If logs ever appear to smoke, turn off re-
place and call a qualified service person.
Note: During initial operation, slight smoking
could occur due to log curing and replace
burning manufacturing residues.
8. To prevent the creation of soot, follow the
instructions in Cleaning and Maintenance,
page 27.
9. Before using furniture polish, wax, carpet
cleaner or similar products, turn replace off.
If heated, the vapors from these products may
create a white powder residue within burner
box or on adjacent walls or furniture.
10. This replace needs fresh air ventilation to run
properly. This replace has an Oxygen Deple-
tion Sensing (ODS) safety shutoff system. The
ODS shuts down the replace if not enough
fresh air is available. See Air for Combustion
and Ventilation, page 6. If replace keeps
shutting off, see Troubleshooting, page 29.
11. Do not run replace
• where ammable liquids or vapors are used
or stored.
• under dusty conditions.
12. Do not use this replace to cook food or burn
paper or other objects.
13. Never place any objects in the replace or
on logs.
14. Do not use replace if any part has been under
water. Immediately call a qualied service
technician to inspect the room replace and to
replace any part of the control system and any
gas control which has been under water.
15. Turn off and unplug replace and let cool
before servicing. Only a qualied service
person should service and repair replace.
16. Operating replace above elevations of 4,500
feet could cause pilot outage.
17. Do not operate replace if log is broken. Do
not operate replace if log is chipped (dime-
sized or larger).
18. To prevent performance problems, do not use
propane/LP fuel tank of less than 100 lbs.
capacity.
19.
Provide adequate clearances around air
openings.