Desa VDCFRPB Outdoor Fireplace User Manual


 
www.desatech.com
116526-01B 25
OPERATING FIREPLACE
Continued


Note: All remote control accessories must
be purchased separately (see Accessories,
page 40). Follow instructions included with
the remote control.

-
Lighting
Instructions
1. After lighting, let pilot flame burn for
about one minute. Turn control knob to
ON position. Adjust ame adjustment knob
anywhere between HI and LO. Slide the
selector switch to the REMOTE position
(see Figure 41). Note: The burner may light
if hand-held remote was on when selector
switch was last turned off. You can now
turn the burner on and off with the hand-
held remote control unit.
IMPORTANT: Do not leave the selector switch
in the REMOTE or ON position when the
pilot is not lit. This will drain the battery.

Hold the control button on the hand-held remote
until burner turns on. Hold the control button
again until burner turns off (see Figure 42).
To Lock press both buttons on hand-held
remote control until light stops ashing. Hand-
held remote control is now locked. If the re is
on it will be turned off automatically. In the
locked state, the light will not light up when
any button is pressed.
To Unlock press both buttons together on
hand-held remote control until the light
stops ashing. The hand-held remote is now
unlocked.
THERMOSTAT SERIES (MODEL

The hand-held remote can be operated using
either the manual mode (MANU) or thermo-
static mode (AUTO) (see Figure 43). To select
Fahrenheit/Centigrade mode display, carefully
press the ˚C/˚F mode button with the end of a
paper clip or similar blunt object.
Figure 41 - Setting the Selector Switch,
Control Knob and Flame Adjustment
Knob for Remote Operation
Flame
Adjustment Knob
Control
Knob
Selector Switch in Remote
Position (Optional Remote Control)
Figure 43 - Thermostat Hand-Held
Remote Control Unit
Manual Mode
1. Press the POWER and LOCK buttons
together to turn on the hand-held remote
control.
2. Press the MANU button to turn on the
replace.
3. Press the POWER and LOCK buttons
together to turn off the replace.
Figure 42 - ON/OFF Hand-Held Remote
Control Unit
Control
Button
Indicator
Light
LOCK
MANU AUTO
ºC/ºF
TEMP
POWER
ROOM
TEMP
SET
TEMP
AUTO
Turns
Hand-Held
Remote On
or Off and
Allows You
to Choose
the Manual
Setting
Selects
AUTO
Mode
°C/°F
Mode
Button
Locks
System to
Prevent
Accidental
Ignition
Turns
Burners
On or
Off
Increases or
Decreases
Room
Temperature
in AUTO Mode
Digital Display Shows
Temperature and Settings
Indicator
Light