Desa (V) CD36T(N Outdoor Fireplace User Manual


 
11
www.desatech.com
116035-01B
VENTING INSTALLATION INSTRUCTIONS
Installation Planning (Cont.)
VENTING INSTALLATION
INSTRUCTIONS
Continued
Horizontal Termination Configuration
Figures 19 through 25 show different configurations and alterna-
tives for venting with horizontal terminations. Each figure includes
a chart with critical minimum and maximum dimensions which
MUST be met.
IMPORTANT:
Remember that a horizontal run of
venting must have a 1/4” rise for every 12” of run toward the termination.
Siding Standoff
Screws
High
Wind
Termination
Apply Mastic to
Outside Edge of
Standoff
Exterior Wall
with
Vinyl Siding
10
3
/4" x 10
3
/4"
Framed
Opening
Maintain
1"
Minimum Air
Space
Around
Outer
Pipe When
Penetrating
a Wall
Minimum
Pipe
Overlap
1
1
/4"
Wall
Firestop
Direct
Vent
Pipe
Figure 17 - Typical Horizontal Termination Cap Mounting with
Additional Siding Standoff Installed
GROUND FLOOR INSTALLATION REAR VENT
Recommended Applications fo Rear Vent Model (V)CD36R:
Installation using cabinet surrounds
Through the wall using round or square termination
(up to a maximum of 18” of horizontal pipe)
Corner installation
(Using one 45° elbow and a maximum of 18” of horizontal pipe).
Vertical (V) Horizontal (H)
25
1
/2 " 22" max.
Square Termination
TOH
Horizontal
Square
Termination
Wall
Firestop
Straight / Adjustable
Pipe 18" Max.
Figure 20 - Horizontal Termination Configuration for Corner
Installation (Model (V)CD36R)
Horizontal
Square
Termination
Wall
Firestop
Straight / Adjustable
Pipe 18" Max.
Corner Installation
Vertical (V) Horizontal (H)
25 ½”
24”
45°
Elbow
90° Elbow
Wall
Firesto
p
Horizontal
Round
Termination
Exterior Portion of Wall
Firestop
(Round
Termination Only)
Figure 19 - Horizontal Termination Configuration for Flush
Installation (Model (V)CD36R)
Figure 18 - Horizontal Termination Configuration for Round
Termination (Model (V)CD36T)