Desa Tech RFP30T Fire Pit User Manual


 
OWNER'S MANUAL
SPECIFICATIONS
BTU (Variable)
Type Gas
Ignition
Pressure Regulator Setting
Inlet Gas Pressure (in. of water) *
Maximum
Minimum
Dimensions, Inches (H x W x D)**
Heater
Carton
Weight (pounds)
Heater
Shipping
•Forpurposesofinput adjustment
•*Measurementincludesknobsandhood.
TECHNICAL
SERVICE
You may have further questions about in-
stallation, ol_ration, or troubleshooting.
If so, contact DESA International's Techni-
cal Service Department at 1-800-323-5190.
15,000/30,000
Propane/LP Only
Piezo
8" W.C.
14"
11"
23.75 x 25.9 x 8.5
26 x 27.75 x 10.25
29
35
SERVICE HINTS
When gas pressure is too low
pilot will notstay lit
burner will have delayed ignition
heater will not produce specified heat
propane/LP gas supply may be low
When gas quality is bad
pilot will not stay lit
burner will produce flames and soot
heater will backfire when lit
You mayfeel your gas pressureis too low or
gas quality is bad. If so, contact your local
prnpane/LP gas supplier.
REPLACEMENT
PARTS
Note: Use only original replacement parts.
This will protect your warranty coverage for
parts replaced under warranty.
Parts Under Warranty
Contact authorized dealers of this product.
If they can't supply original replacement
part(s), either contact your nearest Parts
Central (see below) or call DESA
International's Technical Service Depart-
ment at 1-800-323-5190.
When calling DESA International, have
ready:
your name
your address
model number of your heater
how heater was malfunctioning
type of gasused (propane/LP or natural gas)
purchase date
Usually, we will ask you to return the defec-
tive part to the factory.
Parts Not Under Warranty
Contact authorized dealers of this product.If
theycan 't supplyoriginal replacement part(s),
either contact your nearestParts Central (page
20) or call DESA International's Parts De-
partment at 1-800-972-7879 for referral in-
formation.
When calling DESA International, have
ready:
model number of your heater
the replacement part number
_o44_ 19