Desa Tech RFP30T Fire Pit User Manual


 
15,000 TO 30,000 BTU/HR
OPERATING
HEATER
Continued
LIGHTING
INSTRUCTIONS l
1.
2.
3.
IgnitorButton
STOP! Read the safety information,
page 13, column 3.
Make sure manual shutoff valve is
fully open.
Turn control knob clockwise F-_
to the OFF position.
ControlKnob
Figure 24 - Control Knob In The OFF
Position
4. Wait five (5) minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow "B" in the safety in-
formation page 13, column 3. If you
don't smell gas, go to the next step.
5. Turn control knob counterclockwise
nc_ontrotO the PILOT position. Press
! knob for five (5) seconds
(see Figure 24).
Note: You may be running this
heater for the first time after hook-
ing up to gas supply. If so, the con-
trol knob may need to be pressed in
for 30 seconds. This will allow air to
bleed from the gas system.
If control knob does not pop up
when released, contact a qualified
service person or gas supplier for
repairs.
6. With control knob pressed in, push
down and release ignitor button. This
will light pilot. The pilot is attached to
the front of burner. If needed, keep
pressing ignitor button untilpilot _,hts.
Note: If pilot does not stay lit, refer
to Troubleshooting, pages 16 through
18. Also contact a qualified service
person or gas supplier for repairs.
Until repairs are made, light pilot with
match. To light pilot with match, see
Manual Lighting Procedure.
7. Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knoK
Note: If pilot goes out, repeat steps
3 through 7. This heater has a safety
interlock system. Wait one (1) minute
before lighting pilot again.
8. Turn control knob counterclockwise
to desired heating level. The
main burner should light. Set con-
trol knob to any heat level between
HI and LO.
_]k CAUTION: Do not try to adjust
heating levels by using the
manual shutoff valve.
IgnitorElectrode
Thermocouple
Figure 25 - Pilot
TO TURN OFF GAS 1 2.
TO APPLIANCE BB
Shutting Off Heater
1. Turn control knob clockwise
to the OFF position.
2. Turn off all electric power to the ap-
pliance if service is to be performed.
Shutting Off Burner Only (pilot
stays lit)
Turn control knob dockwlse F-_ to
the PILOT position.
l THERMOSTAT l
CONTROL
OPERATION
The thermostatic control used on this
heater differs from standard thermostats.
Standard thermostats simply turn on and
off the burner. The thermostat used on
this heater senses the room temperature.
The thermostat adjusts the amount of gas
flow to the burner. This increases or de-
creases the burner flame height. At times
the room may exceed the set tempera-
ture. If so, the burner will shut off. The
burner will cycle back on when room
temperature drops below the set tem-
perature.
The control knob can be set to any heat
level between HI and LO.
Note: The thermostat sensing bulb mea-
sures the temperature of air near the
heater cabinet. This may not always agree
with room temperature (depending on
housing construction, installation loca-
tion, room size, open air temperatures,
etc_). Frequent use of your heater will let
you determine your own comfort levels.
l MANUAL LIGHTINGPROCEDURE l
1. Remove front panel (see Figure 2,
page 4).
Follow steps I through 5 under Light-
ing Instructions.
3. With control knob pressed in, strike
match. Hold match to pilot until pi-
lot lights.
4. Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.
5. Replace front panel.
14 1o_._