Cal Flame G4 Gas Grill User Manual


 
6
Installation / Assembly
2009 G3, G4, G5 Grills
LTR20091050, Rev. A
www.calspas.com
LP Gas
Tank Requirements
For plumbed-in LP installation, use a convertible regulator and set it
for LP gas.
Maximum line pressure for plumbed-in propane is 14” WC (3.5 kPa).
Minimum line pressure for propane is 11” WC.
The grill unit must be used with the gas pressure regulator. The regulator
will control and maintain a uniform gas pressure in the manifold. The
burner orices have been sized for the gas pressure delivered by the
regulator.
WARNING: Attempting to operate the grill unit without the gas
regulator installed could cause an explosion and possible death.
Cylinder Specication
Any LP gas supply cylinder used with this grill must be:
Constructed and marked in accordance with the Specications
for LP-Gas Cylinders of the U.S. Department of Transportation
or the National Standard of Canada, CAN/CSA-B339, Cylinders,
Spheres and Tubes for Transportation of Dangerous Goods;
and Commission, as applicable.
Approximately 12 inches in diameter and 18 inches high.