Cal Flame G4 Gas Grill User Manual


 
Installation / Assembly
9
2009 G3, G4, G5 Grills
LTR20091050, Rev. A
www.calspas.com
Leak Testing Procedure
Perform a leak test at least once a year whether the gas supply cylinder
has been disconnected or not. In addition, whenever the gas cylinder
is connected to the regulator or whenever any part of the gas system
is disconnected or replaced, perform a leak test.
As a safety precaution, remember to always leak test your grill outdoors
in a well-ventilated area. Never smoke or permit sources of ignition in
the area while doing a leak test. Do not use a ame, such as a lighted
match to test for leaks. Use a solution of soapy water.
Prepare a leak testing solution of soapy water by mixing in a spray 1.
bottle one part liquid soap to one part water.
Make sure all the control knobs are in the OFF position.2.
Turn on the gas.3.
On a. natural gas systems, turn the main feed valve to the grill.
On b. LP systems, turn the cylinder valve knob counter clockwise
one turn to open.
Apply the leak-testing solution by spraying it on joints of the gas 4.
delivery system. Blowing bubbles in the soap solution indicates
that a leak is present.
Stop a leak by tightening the loose joint or by replacing the faulty 5.
part with a replacement part recommended by the manufacturer.
Do not attempt to repair the cylinder valve if it is damaged. The
cylinder must be replaced.
Turn all control knobs back to the full OFF position.6.
If you are unable to stop a leak:
Turn all control knobs back to the full OFF position.1.
Shut off the gas supply to the grill and release pressure in the 2.
hose and manifold by pushing in and turning any of the control
valves one quarter turn counter-clockwise.
On LP systems, remove the cylinder from the grill.3.
Call an authorized gas appliance service technician or an LP gas 4.
dealer.
Do not use the appliance until the leak is corrected.