Broilmaster P3SXN-1 Gas Grill User Manual


 
B101525-4-0411Page 42
Operating Instructions
Before each use, inspect all hoses. If it is evident there is
excessive abrasion or wear, or the hose is cut, it must be
replaced prior to using your Broilmaster grill. Call your local
Broilmaster dealer for a replacement.
Using the Ignitor
Caution: If a burner fails to light after 5 seconds, turn
the burner OFF for 5 minutes, to allow the gas to clear,
then try again.
Note: Each burner must be lit individually.
1. Turn knob on the grill CLOCKWISE to the OFF posi-
tion.
2. Turn ON gas at the source.
3. With the grill lid open, push and turn the burner control
knob COUNTERCLOCKWISE to Hi.
4. Push and hold the ignitor button until the burner lights
(approximately 5 seconds).
5. If a burner does not light, turn OFF all gas and refer to
the Troubleshooting section of this manual.
6. Repeat steps 3 through 5 for other burner.
Using Matches to Light the Grill
Caution: If a burner fails to light after 5 seconds, turn
the burner OFF for 5 minutes, to allow the gas to clear,
then try again.
Note: Each burner must be lit individually.
1. Turn knob on the grill CLOCKWISE to the OFF posi-
tion.
2. Turn ON gas at the source.
3. Open the grill lid.
4. For Blue Flame grills, insert a burning long wooden match
through the lighter hole on the left side of the grill. For
Infrared grills, insert the lighting stick with a long wooden
match attached through the cooking grid to ignite the
infrared burner from the top. See Figure 35.
5. Turn the burner control knob COUNTERCLOCKWISE to
HI.
6. If a burner does not light, turn OFF all gas and refer to
the Troubleshooting section of this manual.
7. Repeat steps 3 through 6 for other burner.
Checking for Gas Leaks
Check for gas leaks every time you connect your Broilmaster
propane gas grill to a Propane gas cylinder, when a con-
nected cylinder has not been used recently, or when either
a natural or propane grill is being used for the rst time.
Caution: Do not use an open ame when checking for
leaks. Checking for leaks with an open ame may lead
to a re or explosion, resulting in property damage or
personal injury.
To check for gas leaks:
1. Use dish washing liquid and a little water to make a soapy
solution.
2. Turn OFF the knob on the control panel.
3. Turn ON the gas at the supply or cylinder. A hissing
sound indicates a leak. Turn OFF the gas and repair
the leak.
4. Apply the soapy water solution to all gas connections.
5. Look for bubbles. Bubbles indicate a leak.
6. If there are bubbles turn OFF the gas and repair the
leak.
7. Turn the gas back ON and repeat the above procedures
until all leaks are repaired.
Air Shutter Adjustment For R3B Series
Only
The burner (venturi) tube air shutter is preset at the factory
so that after ve minutes the burner ames are blue with well
dened cones. If, after ve minutes the ame is yellow, or
there is a gap between the burner and the ame, adjust the
burner (venturi) tube air shutter as follows:
1. Turn gas OFF and let the burner cool.
2. Beneath the control panel you can access the air
shutter(s) which are located on the end of the burner
tubes.
3. Loosen shutter set screw
4. Close the air shutter to the minimum opening.
5. Light the burner, wait ve minutes and then carefully open
the air shutter until the ame is blue and well dened.
6. Retighten the set screw.
Figure 35
LIGHTING STICK
R734
KEEPHANDAWAY FROM
TOPOFGRILLWHENLIGHTING
INFRARED BURNER
MATCH LIGHT HOLE
BLUE FLAME BURNER
OPERATION - PROPANE & NATURAL GAS GRILLS