Broilmaster D3-1 Gas Grill User Manual


 
B100691-0-0103 Page 17
Gas Type
The type gas required for your grill can be
determined from the product identification label
located on the grills control panel. Questions
regarding different types of gases should be
directed to your local gas supplier.
CAUTION: NEVER USE LIQUID PROPANE (LP) GAS IN
A
GRILL DESIGNED FOR NATURAL GAS, OR NATURAL
GAS
IN A GRILL DESIGNED FOR LIQUID PROPANE GAS.
QUESTIONS REGARDING DIFFERENT TYPES OF GASES
SHOULD
BE DIRECTED TO YOUR LOCAL GAS COMPANY.
Connection Requirements
Installation must conform to local codes or, in the
absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1. In Canada, installation
shall be in accordance with CAN/CGA-B149.2
Propane Installation Code, or CAN/CGA-B149.1
Natural Gas Installation Code, and local codes
where applicable. Contact your local gas
company for code regulations, recommended
procedures, and the installation of your grills gas
supply line.
Broilmaster
®
grills are not equipped with
pressure regulators. Your gas grill operates at a
manifold pressure of seven (7") inches water
column.
Connect cart mounted Natural gas grills to a
pre-installed gas supply line using the twelve
(12) foot flexible hose and quick disconnect kit
which can be purchased from your local dealer.
CAUTION: THE GRILL AND ITS INDIVIDUAL SHUTOFF VALVE
MUST
BE DISCONNECTED FROM THE GAS SUPPLY PIPING
SYSTEM
DURING ANY SYSTEM PRESSURE TESTING AT TEST
PRESSURES
IN EXCESS OF 1/2 PSIG.
CAUTION: THE GRILL MUST BE ISOLATED FROM THE
GAS
SUPPLY PIPING SYSTEM BY CLOSING ITS INDIVIDUAL
MANUAL
SHUTOFF VALVE DURING ANY PRESSURE TESTING
OF
THE GAS SUPPLY PIPING SYSTEM AT TEST PRESSURES
EQUAL
TO OR LESS THAN 1/2 PSIG.
NATURAL GAS GRILLS
Grill Location
When choosing the ideal location for your
Broilmaster
®
Deluxe Gas Grill, remember this
grill is designed for outdoor use ONLY.
You should never install or operate your grill in
any building, garage, or other enclosed area.
For your safety, this grill should not be installed
or operated under any combustible materials,
such as carports, covered porches, awnings, or
overhangs.
Never install or operate your grill in or on any
recreational vehicle or boat.
CAUTION: THE INSTALLATION AND OPERATION OF
THIS
GRILL AT CLEARANCES LESS THAN SPECIFIED BELOW
MAY
LEAD TO THE POSSIBILITY OF FIRE, PROPERTY
DAMAGE
, OR PERSONAL INJURY.
A minimum clearance of sixteen (16") inches is
required from the sides of the grill to any
combustible material.
A minimum clearance of eighteen (18") inches is
required from the back of the grill to any
combustible material.
Some examples of combustible materials are a
wall, a fence, patio furniture, or the wall of your
home.
The area surrounding the grill should be clear to
ensure proper ventilation. Do not obstruct the
flow of combustion and ventilation air in any way.
The ventilation openings on the propane cylinder
enclosure must also remain free and clear of
debris.
Portable grills should be level and positioned
away from direct wind prior to each use.
WARNING: DO NOT INSTALL OR OPERATE THIS GRILL
WHERE
GASOLINE OR OTHER FLAMMABLE MATERIALS ARE
USED
OR STORED. FAILURE TO COMPLY WITH THIS
WARNING
COULD RESULT IN EXPLOSION OR FIRE CAUSING
PROPERTY
DAMAGE OR PERSONAL INJURY.