Bakers Pride Oven XX Gas Grill User Manual


 
The broiler and its individual shutoff valve must be disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of ½ psig (3.45 kPa).
The broiler must be isolated from the gas supply piping system by closing its individual manual shutoff valve
during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ psig (3.45
kPa).
5. BURNERS:
Check to see that AIR MIXER CAPS on the front of all burners are tightened and adjusted, allowing half the
opening to show. Install the burners and deflector shields first following the steps below.
(a) Install all burners with deflector shield assemblies attached.
(B) Place the front of the burner into the valve assembly by fitting the center hole of the mixer cap
over the brass orifice.
(c) Drop the rear end of the burner over the burner support pin on the back of the unit.
6. RADIANTS:
Mount the “V” shaped radiants over the burners with each end mounted on special supports on the front and
rear of the chamber. A radiant should be mounted over each burner assembly.
GS Ceramic Briquettes Option:
The radiants supplied for the GS option are flattened to allow for the installation of an expanded metal grate.
The grate is installed directly on top of the flattened radiant burner shield. Ceramic briquettes are installed on
the grate as shown:
5