Weber 41081 Gas Grill User Manual


 
D-6
Refilling the Liquid Pro-
pane Cylinder
We recommend that you refill the LP cylinder before it
is completely empty.
Removal of the LP cylinder
1) Close cylinder valve (turn clockwise).
2) Unscrew regulator coupling by turning counter-
clockwise, by hand only.
3) Loosen cylinder lock wing nut and turn cylinder
lock up out of the way.
4) Lift cylinder off.
To refill, take LP cylinder to a “Gas Propane” dealer.
ƽ WARNING: We recommend that your LP cylinder
be filled at an authorized LP gas dealer, by a
qualified attendant, who fills the cylinder by
weight. IMPROPER FILLING IS DANGEROUS.
ƽ CAUTION: When transporting the LP cylinder
make sure the plastic dust cover is in place over
the valve. This will keep dust and dirt from the
threaded portion of the valve.
Connecting the Liquid Propane Cylinder
ƽ WARNING: Make sure that the LP cylinder valve
is closed. Close by turning valve clockwise.
ƽ DANGER
Do not use an open flame to check for gas
leaks. Be sure there are no sparks or open
flames in the area while you check for
leaks. Sparks or flames will result in a fire
or explosion which can cause serious
bodily injury or death, and damage to
property.
You will need: LP cylinder, a soap and water solution
and a rag or brush to apply it.
1) Turn the LP cylinder so the opening of the valve is
either to the front, side or rear of the Weber Gas
Barbecue. Lift and hook the cylinder onto the fuel
guage.
(3)
(1)
(2)
Important LP Cylinder Information
Failure to follow these DANGER statements exactly
may result in a fire causing death or serious injury.
ƽDANGER
ƽNEVER store a spare LP Cylinder under or near
this barbecue.
ƽNEVER fill the tank beyond 80% full.
Your Weber gas grill is equipped with a cylinder
supply system designed for vapor withdrawal.
ƽWARNING: Only use this grill outdoors in a well-
ventilated area. Do not use in a garage, building,
breezeway or any other enclosed area.
The LP cylinder supplied with your barbecue is
equipped with an OPD (Overfilling Prevention
Device) and a QCC1 or Type 1 (CGA810) cylinder
connection. The cylinder connection is compatible
with the barbecue connection.
This is a secondary device to prevent the overfilling of
your LP cylinder. The proper filling methods for the
filling of your cylinder are by weight or volume, as
described in NFPA 58. Please make sure your filling
station fills your LP cylinder by weight or volume. Ask
your filling station to read purging and filling instruc-
tions on the LP cylinder before attempting to fill.
ƽWARNING: Do not exchange the LP tank pro-
vided with your barbecue, unless the exchange LP
tank is equipped with an OPD. Otherwise you will
lose the OPD (Overfilling Prevention Device)
feature. If there is not an LP tank available for
exchange equipped with an OPD, we recommend
that you have your LP tank filled at an authorized
LP gas dealer by a qualified attendant.