Weber E/EP - 210/310 Gas Grill User Manual


 
12
WWW.WEBER.COM
®
Check:
1) Hose-to-manifold connection.
ƽ WARNING: If there is a leak at connection (1), retighten the
fitting with a wrench and recheck for leaks with soap and
water solution. If a leak persists after retightening the fitting,
turn OFF the gas. DO NOT OPERATE THE GRILL. Contact
the Customer Service Representative in your area using the
contact information on our web site.
Log onto www.weber.com
®
.
2) Regulator-to-cylinder connection.
3) The hose-to-regulator connection.
4) Valves-to-manifold connections.
ƽ WARNING: If there is a leak at connections (2), (3) or (4),
turn OFF the gas. DO NOT OPERATE THE GRILL. Contact
the Customer Service Representative in your area using the
contact information on our web site.
Log onto www.weber.com
®
.
When leak checks are complete, turn gas supply OFF at the source and rinse
connections with water.
* The grill illustrated may have
slight differences than the
model purchased.
210/310
REFILLING THE LIQUID PROPANE CYLINDER
We recommend that you refill the LP cylinder before it is completely empty.
Removal of the LP cylinder
1) Close cylinder valve (turn clockwise).
2) Unscrew regulator coupling by turning counterclockwise, by hand only.
3) Lift cylinder off.
To fill, take the LP cylinder to a gas propane dealer, or look up “gas-propane” in the
phone book for other sources of LP gas.
ƽ WARNING: We recommend that your LP cylinder be filled
at an authorized LP gas dealer, by a qualified attendant,
who fills the cylinder by weight. IMPROPER FILLING IS
DANGEROUS.
ƽ CAUTION: Place dust cap on cylinder valve outlet whenever
the cylinder is not in use. Only install the type of dust cap
on the cylinder valve outlet that is provided with the cylinder
valve. Other types of caps or plugs may result in leakage of
propane.
GAS INSTRUCTIONS