Weber 89173 Gas Grill User Manual


 
10
CHECK:
A) Bulkhead and gas supply hose connection (1).
B) Main gas line to manifold connections (2).
m WARNING: If there is a leak at connection (1, or 2), retighten
the fitting with a wrench and recheck for leaks with soap and
water solution.
If a leak persists after re-tightening the fitting, turn off the gas.
DO NOT OPERATE THE GRILL. Contact the Customer Service
Representative in your area using the contact information on
our web site. Log onto www.weber.com
®
.
C) Side burner hose to bulkhead connection (3).
D) Side burner hose to Quick disconnect connection, side burner valve and orifice
connections (4).
E) Regulator to cylinder connection (5).
F) Hose to regulator connection (6).
G) Valves to manifold connections (7).
m WARNING: If there is a leak at connections (3, 4, 5, 6 or 7),
turn off the gas. DO NOT OPERATE THE GRILL. Contact
the Customer Service Representative in your area using the
contact information on our web site.
Log onto www.weber.com
®
.
When leak checks are complete, turn gas supply off at the source and rinse connections
with water.
1
2
3
4
5
6
7
* The grill illustrated may have
slight differences than the
model purchased.
620
gaS inStrUctionS