GAS INSTRUcTIoNS
8
3
7
1
2
6
4
5
1 Main gas line
2 Shut off valve
3
Corrugated gas line
to manifold
4 3/8" (1.27mm) flared gasket
5 Cap (optional side burner)
6 Regulator (not included)
7
1/2" (1.27mm) SAE 45
adapter fitting
8 Gas flow
TYPE OF GAS
Your natural gas grill is factory built to operate using natural gas only. Never attempt to
operate your grill on gases other than the type specified on the grill rating plates.
Your grill operates at 4.5" of water column pressure. If replacement of the hose becomes
necessary, factory specified parts are required. See your local dealer.
For safety and design reasons, the conversion of a Weber
®
grill from operation using
Natural gas to operation using LP gas requires the change out of the entire gas
supply system of the grill. If this becomes necessary, see your dealer for additional
information.
WHAT IS NATURAL GAS?
Natural gas, often called methane, is a safe modern fuel. Natural gas is supplied by your
local utility and should be readily available if your house is already heated with gas.
LEAK CHECK PREPARATION
Check that all burner valves are off
Valves are shipped in the “OFF” position, but you should check to be sure that they are
turned off. Check by pushing in and turning clockwise. If they do not turn, they are off.
Proceed to the next step. If they do turn continue turning them clockwise until they stop,
then they are off. Proceed to the next step.