Weber 56204 Gas Grill User Manual


 
20
SIDE bURNER IGNITIoN & USAGE
3
1
2
5
2 4
OFF
START/HI
LOW
m DANGER
Failure to open the lid while igniting the side burner, or not
waiting 5 minutes to allow the gas to clear if the side burner
does not light, may result in an explosive flare-up which can
cause serious bodily injury or death.
m WARNING: Check hose before each use of barbecue for
nicks, cracking, abrasions or cuts. If the hose is found to
be damaged in any way, do not use the barbecue. Replace
using only Weber
®
authorized replacement hose. Contact
the Customer Service Representative in your area using the
contact information on our web site.
Log onto www.weber.com
®
.
A) Open the side burner lid (1).
B) Check that the side burner valve is turned off (2) (Push control knob in and turn
clockwise to ensure that it is in the OFF position), turn all burners not being used to
the OFF position (push in and turn clockwise).
m WARNING: The burner control knobs must be in the OFF
position before turning on the liquid propane cylinder valve.
If they are not in the OFF position, when you turn on the LP
cylinder valve, the “excess gas flow control” feature will
activate, limiting the flow of gas from the LP cylinder. If this
should occur, turn OFF the LP tank valve and burner control
knobs. Start over.
m DANGER
When the “excess gas flow control” feature is activated,
a small amount of gas is still flowing to the burners. After
turning OFF the cylinder and burner control knobs, wait at
least 5 minutes for the gas to clear before attempting to light
the barbecue. Failure to do so may result in an explosive
flare-up, which can cause serious bodily injury or death.
C) Turn the gas supply valve on (3).
D) Push down and turn the side burner control valve to START/HI (4).
E) Press the igniter button several times so it clicks each time until you see a flame (5).
m CAUTION: Side burner flame may be difficult to see on a
bright sunny day.
m WARNING: If the side burner does not light in 5 seconds:
a) Turn off the side burner control valve, main burners
and gas supply at source.
b) Wait 5 minutes to let the gas clear before you try
again, or try lighting with a match (see “SIDE BURNER
MANUAL IGNITION”).