ƽ CAUTION: Place dust cap on cylinder valve outlet
whenever the cylinder is not in use. Only install the
type of dust cap on the cylinder valve outlet that is
provided with the cylinder valve. Other types of caps
or plugs may result in leakage of propane.
Do not use a damaged LP cylinder. Dented or rusty LP cylinders or
LP cylinders with a damaged valve may be hazardous and should be
replaced with a new one immediately.
Liquid Propane (LP) Cylinder(s)
The joint where the hose connects to the LP cylinder must be leak tested
each time the LP cylinder is reconnected. For example, test each time the
LP cylinder is refi lled.
Be sure the regulator is mounted with the small vent hole pointed
downward so that it will not collect water. This vent should be free of dirt,
grease, bugs etc.
The gas connections supplied with your Weber
®
gas barbecue have been
designed and tested to meet 100% CSA and ANSI requirements.
ƽ WARNING: Replacement LP tanks must match the
regulator connection supplied with this barbecue.
Liquid Propane Cylinder requirements
DOT 4BA240
00/02
(1)
(2)
Check to be sure cylinders have a D.O.T. certifi cation (1), and date tested
(2) is within fi ve years. Your LP gas supplier can do this for you.
All LP tank supply systems must include a collar to protect the cylinder
valve.
The LP cylinder must be a 20-lb. size approximately (18 1/4 inches high,
12 1/4 inches in diameter).
The cylinder should be constructed and marked in accordance with
the Specifi cations for LP - Gas Cylinders of the U.S. Department of
Transportation (D.O.T.) or the National Standard of Canada, CAN/CSA-
B339, Cylinders, Spheres and Tubes or Transportation of Dangerous
Goods; and Commission, as applicable.
In Canada
Liquid Propane Cylinder requirements
Note: Your retailer can help you match a replacement tank to your barbecue
The LP cylinder must be constructed and marked in accordance with the
specifi cations for LP gas cylinders, T.C.
GAS INSTRUCTIONS